Page 74 - Lewisham SuDS DESIGN & EVALUATION
P. 74

Detailed Design  9.3  Typical Detailed Design package

           The Detailed Design package should be
           proportionate to the scale of the
           development and will generally encompass a
           design statement with accompanying

           drawings. Supporting information including
           calculations, maintenance plan and risk
           assessment will also be required.




           9.3.1  SuDS Design Statement


           The SuDS Design Statement should cover                    ■  outline how requirements of NPPF, NSTS,
           SuDS provisions on quantity, quality, amenity             local SuDS policies, requirements for
           and biodiversity and how opportunities                    multi-functional use of SuDS space and
           provided by the site have been maximised                  local objectives for sustainability including
           along with addressing the following:                      climate resilience are dealt with

              ■  confirm drainage design criteria agreed             ■  explain how SuDS will function passively
               with LPA. For example, rainfall return                in terms of treatment and management
               periods, discharge allowance, traffic
               loading requirements etc                              ■  outline details of any offsite works
  69          ■  summarise the findings of the FRA and               required, together with any necessary
                                                                     consents.
               highlight any other significant site

               constraints

































           Lewisham Council SuDS D & E Guide                                                                       © 2018 McCloy Consulting & Robert Bray Associates
   69   70   71   72   73   74   75   76   77   78   79