Page 106 - 2018_IMC
P. 106

CHAPTER 9

                                   SPECIFIC APPLIANCES, FIREPLACES
                                 AND SOLID FUEL-BURNING EQUIPMENT




             User note:
                About this chapter: Chapter 9 focuses on specific types of appliances and fireplaces. It also addresses heat-rejection equipment, combus-
                tion engines, gas turbines, kilns, fuel cells, evaporative coolers, radiant heating systems and hydrogen systems.



                               SECTION 901                        fireplace system  has been  specifically tested,  listed and
                                 GENERAL                          labeled for such use in accordance with UL 127.
             901.1 Scope. This chapter shall govern the approval, design,  903.4 Gasketed fireplace doors. A gasketed fireplace door
             installation, construction, maintenance, alteration and repair  shall not be installed on a factory-built fireplace except where
             of the appliances and equipment specifically identified herein  the fireplace system has been specifically tested, listed and
             and factory-built fireplaces. The approval, design, installa-  labeled for such use in accordance with UL 127.
             tion, construction, maintenance, alteration and repair of gas-
             fired appliances shall be regulated by the International Fuel
             Gas Code.
                                                                                    SECTION 904
             901.2 General. The requirements of this chapter shall apply  PELLET FUEL-BURNING APPLIANCES
             to the mechanical equipment and appliances regulated by this  904.1 General. Pellet fuel-burning appliances shall be listed
             chapter, in addition to the other requirements of this code.
                                                                  and labeled in accordance with ASTM E1509 and shall be
             901.3 Hazardous locations. Fireplaces and solid fuel-burn-  installed in accordance with the terms of the listing.
             ing appliances shall not be installed in hazardous locations.
             901.4  Solid  fuel-burning  fireplaces  and  appliances  in
             Group I-2, Condition 2. In Group I-2, Condition 2 occupan-             SECTION 905
             cies, solid fuel-burning fireplaces and appliances are prohib-  FIREPLACE STOVES AND ROOM HEATERS
             ited.
                                                                  905.1  General.  Fireplace stoves and solid-fuel-type  room
                                                                  heaters shall be listed and labeled and shall be installed in
                               SECTION 902                        accordance with the conditions of the listing. Fireplace stoves
                          MASONRY FIREPLACES                      shall be tested in accordance with UL 737. Solid-fuel-type
                                                                  room heaters shall be tested  in accordance with UL 1482.
             902.1  General. Masonry fireplaces shall be constructed in  Fireplace inserts intended for installation in fireplaces shall
             accordance with the International Building Code.
                                                                  be listed and labeled in accordance with the requirements of
             902.2  Fireplace  accessories. Listed and labeled fireplace  UL 1482 and shall be installed in accordance with the manu-
             accessories shall be installed in accordance with the condi-  facturer’s instructions.
             tions of the listing and the manufacturer’s instructions.  Fire-
             place accessories shall comply with UL 907.          905.2 Connection to fireplace. The connection of solid fuel
                                                                  appliances to chimney flues serving fireplaces shall comply
                                                                  with Sections 801.7 and 801.10.
                               SECTION 903                        905.3  Hearth  extensions.   Hearth extensions for fireplace
                       FACTORY-BUILT FIREPLACES                   stoves shall be installed in accordance with the listing of the

             903.1  General. Factory-built fireplaces shall be  listed and  fireplace stove.  The hearth extension shall be readily distin-
             labeled and shall be installed in accordance with the condi-  guishable from the surrounding floor area.  Listed and labeled
             tions of the listing. Factory-built fireplaces shall be tested in  hearth extensions shall comply with UL 1618.
             accordance with UL 127.
             903.2 Hearth extensions. Hearth extensions of approved fac-
             tory-built fireplaces shall be installed in accordance with the        SECTION 906
             listing of the fireplace. The hearth extension shall be readily  FACTORY-BUILT BARBECUE APPLIANCES
             distinguishable from the surrounding floor area. Listed and  906.1 General. Factory-built barbecue appliances shall be of
             labeled hearth extensions shall comply with UL 1618.  an approved type and shall be installed in accordance with
             903.3 Unvented gas log heaters. An unvented gas log heater  the manufacturer’s instructions, this chapter and Chapters 3,
             shall not be installed in a factory-built fireplace unless the  5, 7 and 8, and the International Fuel Gas Code.




             2018 INTERNATIONAL MECHANICAL CODE                                                                  89
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
   101   102   103   104   105   106   107   108   109   110   111