Page 252 - 2018_IRC
P. 252
WALL CONSTRUCTION
STUD
MINIMUM
6″
TRACK
NO. 8 SCREW THROUGH
EACH FLANGE
4 NO. 8 SCREWS THROUGH
EACH FLANGE
STUD BLOCKING INSIDE WALL TRACK
(MINIMUM THICKNESS OF STUD)
ANCHOR BOLT OR OTHER CONNECTION
AS REQUIRED
FOUNDATION OR SLAB ON GRADE
SILL SEALER AS REQUIRED
For SI: 1 inch = 25.4 mm.
FIGURE R603.3.1(2)
WALL TO FOUNDATION CONNECTION
SPACING OF PLATES
STUD
MINIMUM 3″ x 4″ x 33 MIL
METAL PLATE
TRACK
4-10d OR 6-8d COMMON NAIL
NO. 8 SCREW THROUGH EACH FLANGE
MINIMUM 4 NO. 8 SCREWS
ANCHOR BOLT THROUGH WOOD SILL
OR OTHER CONNECTION AS REQUIRED
WOOD SILL
FOUNDATION OR SLAB ON GRADE
For SI: 1 mil = 0.0254 mm, 1 inch = 25.4 mm.
FIGURE R603.3.1(3)
WALL TO WOOD SILL CONNECTION
2018 INTERNATIONAL RESIDENTIAL CODE ® 227
Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.