WALL CONSTRUCTION



                       STUD SPACING                                    R603.9.2.1 Full height sheathing. The minimum per-
                                                                       centage of full-height structural sheathing shall be mul-
                                                                       tiplied  by  1.10  for  9-foot-high  (2743  mm)  walls  and
                                                                       multiplied by 1.20 for 10-foot-high (3048 mm) walls.
                                                                       R603.9.2.2 Full-height sheathing in lowest story. In
                                                                       the lowest story of a dwelling, multiplying the percent-
                                                                       age  of  full-height  sheathing  required  in  Table
                                                                       R603.9.2(1) by 0.6 shall be permitted where hold-down
                                                                       anchors  are  provided  in  accordance  with  Section
                                                                       R603.9.4.2.
                    WALL HEIGHT          STRUCTURAL SHEATHING        R603.9.3  Structural  sheathing  fastening.  Edges  and
                                                                     interior areas of structural sheathing panels shall be fas-
                                         PANEL
                                         FIELD FASTENER              tened to framing members and tracks in accordance with
                                                                     Figure R603.9 and Table R603.3.2(1). Screws for attach-
                                         EDGE FASTENER
                                                                     ment  of  structural  sheathing  panels  shall  be  bugle-head,
                                                                     flat-head,  or  similar  head  style  with  a  minimum  head
                                FIGURE R603.9
                   STRUCTURAL SHEATHING FASTENING PATTERN            diameter of 0.29 inch (8 mm).
                                                                       For  continuously  sheathed  braced wall lines  using
               R603.9.1 Sheathing materials. Structural sheathing pan-  wood structural panels installed with No. 8 screws spaced
                                        7
               els shall consist of minimum  / -inch-thick (11 mm) ori-  4  inches  (102  mm)  on  center  at  all  panel  edges  and  12
                                         16
               ented strand board or  / -inch-thick (12 mm) plywood.  inches  (304.8  mm)  on  center  on  intermediate  framing
                                 15
                                   32
               R603.9.2  Determination  of  minimum  length  of  full-  members, the following shall apply:
               height  sheathing.  The  minimum  length  of  full-height  1. Multiplying the percentages of full-height sheathing
               sheathing on each braced wall line shall be determined by  in Table R603.9.2(1) by 0.72 shall be permitted.
               multiplying the length of the braced wall line by the per-  2. For bottom track attached to foundations or framing
               centage obtained from Table R603.9.2(1) and by the plan   below, the bottom track anchor or screw connection
               aspect-ratio  adjustment  factors  obtained  from  Table  spacing in Tables R505.3.1(1) and R603.3.1 shall be
               R603.9.2(2). The minimum length of full-height sheathing  multiplied by two-thirds
               shall be not less than 20 percent of the braced wall line
               length.                                               R603.9.4  Uplift  connection  requirements.  Uplift  con-
                                                                     nections shall be provided in accordance with this section.
                  To  be  considered  full-height  sheathing,  structural
               sheathing shall extend from the bottom to the top of the  R603.9.4.1 Ultimate design wind speeds greater than
               wall without interruption by openings. Only sheathed, full-  130 mph. Where ultimate design wind speeds exceed
               height wall sections, uninterrupted by openings, which are  130  miles  per  hour  (58  m/s),  Exposure  Category  C
               not less than 48 inches (1219 mm) wide, shall be counted  walls shall be provided with direct uplift connections in
               toward  meeting  the  minimum  percentages  in  Table   accordance with AISI S230, Section E13.3, and AISI
               R603.9.2(1). In addition, structural sheathing shall comply  S230, Section F8.2, as required for 140 miles per hour
               with all of the following requirements:                 (63 m/s), Exposure Category C.
                  1. Be installed with the long dimension parallel to the  R603.9.4.2 Hold-down anchor. Where the percentage
                    stud framing and shall cover the full vertical height of  of full-height sheathing is adjusted in accordance with
                    wall from the bottom of the bottom track to the top of  Section  R603.9.2.2,  a  hold-down  anchor,  with  a
                    the top track of each story. Installing the long dimen-  strength of 4,300 pounds (19 kN), shall be provided at
                    sion  perpendicular  to  the  stud  framing  or  using  each end of each full-height sheathed wall section used
                    shorter segments shall be permitted provided that the  to meet the minimum percent sheathing requirements of
                    horizontal joint is blocked as described in Item 2.  Section R603.9.2. Hold-down anchors shall be attached
                                                                       to back-to-back studs; structural sheathing panels shall
                  2. Be  blocked  where  the  long  dimension  is  installed  have  edge  fastening  to  the  studs,  in  accordance  with
                    perpendicular to the stud framing. Blocking shall be  Section R603.9.3 and AISI S230, Table E11-1.
                    not less than 33 mil (0.84 mm) thickness. Each hori-
                    zontal  structural  sheathing  panel  shall  be  fastened  A single hold-down anchor, installed in accordance
                    with No. 8 screws spaced at 6 inches (152 mm) on   with Figure R603.9.4.2, shall be permitted at the cor-
                    center to the blocking at the joint.               ners of buildings.
                  3. Be applied to each end (corners) of each of the exte-  R603.9.5 Structural sheathing for stone and masonry
                    rior walls with a minimum 48-inch-wide (1219 mm)  veneer. Where stone and masonry veneer are installed in
                    panel.                                           accordance with Section R703.8, the length of full-height
                                                                     sheathing  for  exterior  and  interior  wall  lines  backing  or
                  Exception: Where stone or masonry veneer is installed,  perpendicular to and laterally supporting walls with veneer
                  the required length of full-height sheathing and over-  shall comply with this section.
                  turning  anchorage  required  shall  be  determined  in
                  accordance with Section R603.9.5.

             2018 INTERNATIONAL RESIDENTIAL CODE ®                                                               257