Page 283 - 2018_IRC
P. 283

WALL CONSTRUCTION



                                                     TABLE R603.9.2(1)
                       MINIMUM PERCENTAGE OF FULL-HEIGHT STRUCTURAL SHEATHING ON EXTERIOR WALLS a, b
                                                                    ULTIMATE WIND SPEED AND EXPOSURE
                                                                                (mph)
                  WALL SUPPORTING          ROOF SLOPE                       130 B    < 140 B
                                                        115 B     120 B                       < 130 C   < 140 C
                                                                            115 C    120 C
                                              3  :  1  2  9        1  1      1  1     1  3      1  7      2  0
         Roof and ceiling only (one story or top   6:12  13        15        17       22        28        35
         floor of two- or three-story building)  9:12    23        27        29       33        53        59
                                             1  2  :  1  2  3  2   3  9      4  0     4  4      7  0      7  6
                                              3:12       26        32        34       39        53        67
         One story, roof and ceiling (first floor of a   6:12  27  33        34       44        61        75
         two-story building or second floor of a
         three-story building)                9:12       38        45        46       61        78        92
                                             12:12       43        53        57       72        106      116
                                              3:12       43        53        57       64        89       113
         Two stories, roof and ceiling (first floor of   6:12  41  51        51       67        95       114
         a three-story building)              9:12       53        63        63       89        104      126
                                             12:12       54        67        74       100       142      157
         For SI: 1 mph = 0.447 m/s.
         a. Linear interpolation is permitted.
         b. For hip-roofed homes the minimum percentage of full-height sheathing, based on wind, is permitted to be multiplied by a factor of 0.95 for roof slopes not
           exceeding 7:12 and a factor of 0.9 for roof slopes greater than 7:12.

                                                     TABLE R603.9.2(2)
                                    FULL-HEIGHT SHEATHING LENGTH ADJUSTMENT FACTORS
                                                                  LENGTH ADJUSTMENT FACTORS
                   PLAN ASPECT RATIO
                                                         Short wall                        Long wall
                         1:1                               1.0                               1.0
                        1.5:1                              1.5                               0.67
                         2:1                               2.0                               0.50
                         3:1                               3.0                               0.33
                         4:1                               4.0                               0.25


                            DOUBLE STUDS BACK-TO-BACK WITH              DOUBLE ROW OF NO. 8 SCREWS
                            OUTSIDE STUD CAPPED WITH TRACK              AT 12 IN. O.C.
                            NO. 8 SHEATHING ATTACHMENT                  HOLD DOWN AS REQUIRED BY
                            SCREWS AS REQUIRED BY                       SECTION R603.9.4
                            SECTION R603.9.3
                            NO. 8 SCREWS ATTACHING
                            TRACK TO STUD AT 8 IN.
                            O.C. EACH FLANGE


                                                                          INSIDE FACE
                            PLYWOOD, OSB OR GWB                         WALLBOARD BACKING STUDS
                            SHEATHING PER SHEARWALL
                            REQUIREMENTS

                                      OUTSIDE FACE                    INSIDE FACE




         For SI: 1 inch = 25.4 mm.
                                                     FIGURE R603.9.4.2
                                              CORNER STUD HOLD-DOWN DETAIL

         258                                                                 2018 INTERNATIONAL RESIDENTIAL CODE  ®
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
   278   279   280   281   282   283   284   285   286   287   288