WALL COVERING








                              ROOFING





                                                                             WALLBOARD





                              MIN. CLEARANCE
                              OF ¾-IN.                                   1-IN. AIRSPACE OR
                                          METAL TIE b                    1-IN. GROUTED SPACE c

                              WATER-RESISTIVE BARRIER b
                                                                        MASONRY VENEER






                                                                             WALLBOARD
                               WATER-RESISTIVE BARRIER b
                                           FLASHING a
                                                                             INSULATION
                                                                             BETWEEN STUDS
                                        STEEL LINTEL d


                                          WEEPHOLE a




                                            SEALANT
                                     MASONRY VENEER
         For SI: 1 inch = 25.4 mm.
         a. See Sections R703.4, R703.8.5 and R703.8.6.
         b. See Sections R703.2 and R703.8.4.
         c. See Table R703.8.4 and Section R703.8.4.2.
         d. See Section R703.8.3.
         e. Figure R703.8 illustrates typical construction details for a masonry veneer wall. For the actual mandatory requirements of this code, see the indicated
           sections of text. Other details of masonry veneer wall construction shall be permitted provided the requirements of the indicated sections of text are met.

                                                  FIGURE R703.8—continued
                                           TYPICAL MASONRY VENEER WALL DETAILS e

                                                                             7
              R703.8.2.1 Support by steel angle. A minimum 6-inch  tion or two  / -inch (11.1 mm) bolts with washers for
                                                                              16
                         5
              by 4-inch by  / -inch (152 mm by 102 mm by 8 mm)     cold-formed  steel  construction.  The  steel  angle  shall
                          16
              steel angle, with the long leg placed vertically, shall be  have a minimum clearance to underlying construction of
              anchored to double 2-inch by 4-inch (51 mm by 102    1 /  inch (1.6 mm). Not less than two-thirds the width of
                                                                    16
              mm) wood studs or double 350S162 cold-formed steel   the  masonry  veneer  thickness  shall  bear  on  the  steel
              studs at a maximum on-center spacing of 16 inches (406  angle. Flashing and weep holes shall be located in the
              mm). Anchorage of the steel angle at every double stud  masonry veneer in accordance with Figure R703.8.2.1.
                                         7
              spacing shall be not less than two  / -inch-diameter (11  The maximum height of masonry veneer above the steel
                                          16
              mm) by 4-inch (102 mm) lag screws for wood construc-  angle support shall be 12 feet 8 inches (3861 mm). The