Page 402 - 2018_IRC
P. 402
WALL COVERING
Zone 5, Exposure D — 12/12 12/12 16/12, 12/16, 12/12 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12
140 mph V Ultimate Zone 5, Exposure C — 16/12, 12/16, 12/12 16/12, 12/16, 12/12 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12
Zone 5, Exposure B 12/12 16/16, 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12
REQUIRED BRICK-TIE SPACING (VERTICAL-TIE SPACING/HORIZONTAL-TIE SPACING) (inches/inches)
Zone 5, Exposure D — 16/12, 12/16, 12/12 16/12, 12/16, 12/12 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12
130 mph V Ultimate Zone 5, Exposure C 12/12 16/12, 12/16, 12/12 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12
Zone 5, Exposure B 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12
TABLE R703.8.4(2) REQUIRED BRICK TIE SPACING FOR DIRECT APPLICATION TO WOOD STRUCTURAL PANEL SHEATHING a, b, c Zone 5, Exposure D 12/12 16/16, 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12 This table is based on attachment of brick ties directly to wood structural panel sheathing only. Additional attachment of the brick tie to lumber framing is not r
115 mph V Ultimate Zone 5, Exposure C 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12
Zone 5, Exposure B 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12 Fasteners shall be sized such that the tip of the fastener passes completely through the wood structural panel sheathing by not less than 1 / 4 inch.
Zone 5, Exposure D 12/12 16/16, 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12 Foam sheathing shall have a minimum compressive strength of 15 psi in accordance with ASTM C578 or ASTM C1289.
110 mph V Ultimate Zone 5, Exposure C 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12 Wood structural panels shall have a specific gravity of 0.42 or greater in accordance with NDS.
Zone 5, Exposure B 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12 24/16, 16/24, 16/16, 16/12, 12/16, 12/12
SIZE (DIA. OR SCREW #) 0.091 0.148 #6 #8 #10 #14 1 inch = 25.4 mm, 1 mph = 0.447 m/s.
FASTENER TYPE d Ring Shank Nails Screws For SI: less.
2018 INTERNATIONAL RESIDENTIAL CODE ® a. b. c. d. 377
Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.