Page 445 - 2018_IRC
P. 445

ROOF-CEILING CONSTRUCTION



                                                                   STRAP BRACING, INSTALL TAUT,
                                                                   USE 1 NO. 8 SCREW TO EACH JOIST.
                 ANCHORAGE AT
                 END IS REQUIRED.
                                                                                       SHORT SEGMENT OF
                                                                                       STUD OR TRACK
                                                                                       USED AS BLOCKING:
                                                                                       AT STRAP SPLICE
                                                                                       LOCATIONS, AT ENDS,
                                                                                       AND AT MAX. 12 FT O.C.

















           For SI: 1 foot = 304.8 mm.
                                                    FIGURE R804.3.1.3(2)
                         CEILING JOIST TOP FLANGE BRACING WITH CONTINUOUS STEEL STRAP AND BLOCKING










                                                         6 IN. MIN
                                                                                      C-SHAPE OR TRACK
                                                                                      SECTION WITH
                                                        3 IN. MIN.
                                                                                      MINIMUM SIZE AND
                                                                                      THICKNESS AS
                                                                                      CEILING JOIST
                       CEILING JOIST

                        NUMBER OF SCREWS
                        ON EACH SIDE OF                                               CEILING JOIST
                        SPLICE SHALL BE THE
                        SAME AS REQUIRED
                        FOR THE HEEL JOINT
                        CONNECTION




                     TRACK


                         LOAD-BEARING STUD





         For SI: 1 inch = 25.4 mm.
                                                     FIGURE R804.3.1.4
                                                  SPLICED CEILING JOISTS




         420                                                                 2018 INTERNATIONAL RESIDENTIAL CODE  ®
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.