Page 451 - 2018_IRC
P. 451

ROOF-CEILING CONSTRUCTION




                      CEILING JOISTS


                   FLAT STUD OR TRACK
                   BLOCKING AT 48 IN. O.C.
                   AT FIRST TWO JOIST
                   SPACES


                   3 NO. 8 SCREWS AT
                   EACH STUD





                                                             NO. 8 SCREWS AT
                      STUD BLOCKING                          6 INCHES O.C. TO
                      AT CEILING                             FLAT BLOCKING             WOOD STRUCTURAL
                      ELEVATION                                                        PANEL OR GYPSUM
                                                                                       BOARD DIAPHRAGM
                           GABLE
                           ENDWALL
                           STUDS
         For SI: 1 inch = 25.4 mm.
                                                    FIGURE R804.3.7.1(1)
                                        CEILING DIAPHRAGM TO GABLE ENDWALL DETAIL










                 ROOF SHEATHING                                                           ROOF RAFTER
                                                                                          (OR TRUSS TOP CHORD)

                  ROOF BLOCKING


                                                                                          CEILING JOIST
                                                                                          (OR TRUSS BOTTOM CHORD)
           NO. 8 SCREWS AT 6 IN. O.C.







                                                                                          WOOD STRUCTURAL
                                                                                          PANEL OR GYPSUM
                STRUCTURAL WALL
                                                                                          BOARD DIAPHRAGM
                                                                                          350T125-33 TRACK
                                                                                          BLOCKING

         For SI: 1 inch = 25.4 mm.
                                                    FIGURE R804.3.7.1(2)
                                           CEILING DIAPHRAGM TO SIDEWALL DETAIL







         426                                                                 2018 INTERNATIONAL RESIDENTIAL CODE  ®
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
   446   447   448   449   450   451   452   453   454   455   456