P. 468

ROOF ASSEMBLIES



                              TABLE R905.10.3(2)                     R905.12.1  Slope.  Thermoset  single-ply  membrane  roofs
                       MINIMUM CORROSION RESISTANCE
                                                                     shall have a design slope of not less than one-fourth unit
             55% aluminum-zinc-alloy-coated steel   ASTM A792 AZ 50   vertical in 12 units horizontal (2-percent slope) for drain-
             5% aluminum alloy-coated steel   ASTM A875 GF60         age.
             Aluminum-coated steel           ASTM A463 T2 65         R905.12.2  Material  standards.  Thermoset  single-ply
             Galvanized steel                ASTM A653 G-90          roof coverings shall comply with ASTM D4637 or ASTM
                                                                     D5019.
                                                      a
             Prepainted steel                ASTM A755
                                                                     R905.12.3 Application. Thermoset single-ply roofs shall
             a. Paint systems in accordance with ASTM A755 shall be applied over steel  be installed in accordance with this chapter and the manu-
               products with corrosion-resistant coatings complying with ASTM A792,
               ASTM A875, ASTM A463, or ASTM A653.                   facturer’s instructions.
               R905.10.4  Attachment.  Metal  roof  panels  shall  be  R905.13 Thermoplastic single-ply roofing. The installation
               secured to the supports in accordance with this chapter and  of thermoplastic single-ply roofing shall comply with the pro-
               the manufacturer’s installation instructions. In the absence  visions of this section.
               of  manufacturer’s  installation  instructions,  the  following
               fasteners shall be used:                              R905.13.1  Slope.  Thermoplastic  single-ply  membrane
                                                                     roofs shall have a design slope of not less than one-fourth
                  1. Galvanized fasteners shall be used for steel roofs.
                                                                     unit vertical in 12 units horizontal (2-percent slope).
                  2. Copper, brass, bronze, copper alloy and  300-series
                    stainless steel fasteners shall be used for copper roofs.  R905.13.2 Material standards. Thermoplastic single-ply
                                                                     roof coverings shall comply with ASTM D4434, ASTM
                  3. Stainless  steel  fasteners  are  acceptable  for  metal  D6754 or ASTM D6878.
                    roofs.
                                                                     R905.13.3  Application.  Thermoplastic  single-ply  roofs
               R905.10.5  Underlayment.  Underlayment  shall  comply  shall be installed in accordance with this chapter and the
               with Section R905.1.1.                                manufacturer’s instructions.
             R905.11  Modified  bitumen  roofing.  The  installation  of  R905.14 Sprayed polyurethane foam roofing. The installa-
             modified bitumen roofing shall comply with the provisions of  tion of sprayed polyurethane foam roofing shall comply with
             this  section  and  the  manufacturer’s  approved  installation  the provisions of this section.
             instructions.
                                                                     R905.14.1 Slope. Sprayed polyurethane foam roofs shall
               R905.11.1 Slope. Modified bitumen roofing shall have a  have a design slope of not less than one-fourth unit verti-
               design slope of not less than one-fourth unit vertical in 12  cal in 12 units horizontal (2-percent slope) for drainage.
               units horizontal (2-percent slope) for drainage.
                                                                     R905.14.2  Material  standards.  Spray-applied  polyure-
               R905.11.2 Material  standards. Modified bitumen roof-  thane  foam  insulation  shall  comply  with  ASTM  C1029,
               ing shall comply with the standards in Table R905.11.2.  Type III or IV or ASTM D7425.
                               TABLE R905.11.2                       R905.14.3 Application. Foamed-in-place roof insulation
                MODIFIED BITUMEN ROOFING MATERIAL STANDARDS          shall be installed in accordance with this chapter and the
                   MATERIAL                STANDARD                  manufacturer’s  instructions.  A  liquid-applied  protective
             Acrylic coating     ASTM D6083                          coating  that  complies  with  Table  R905.14.3  shall  be
             Asphalt adhesive    ASTM D3747                          applied not less than 2 hours nor more than 72 hours fol-
             Asphalt cement      ASTM D3019                          lowing the application of the foam.
             Asphalt coating     ASTM D1227; D2824
                                                                                    TABLE R905.14.3
             Asphalt primer      ASTM D41                               PROTECTIVE COATING MATERIAL STANDARDS
             Modified bitumen roof   ASTM D6162; D6163; D6164;                MATERIAL                STANDARD
             membrane            D6222; D6223; D6298
                                                                   Acrylic coating                   ASTM D6083
                  R905.11.2.1  Base  sheet.  A  base  sheet  that  complies  Silicone coating        ASTM D6694
                  with the requirements of Section 1507.11.2 of the Inter-  Moisture-cured polyurethane coating  ASTM D6947
                  national Building  Code,  ASTM  D1970,  or  ASTM
                  D4601 shall be permitted to be used with a modified  R905.14.4  Foam  plastics.  Foam  plastic  materials  and
                  bitumen cap sheet.                                 installation shall comply with Section R316.

               R905.11.3 Application. Modified bitumen roofs shall be  R905.15 Liquid-applied roofing. The installation of liquid-
               installed in accordance with this chapter and the manufac-  applied roofing shall comply with the provisions of this sec-
               turer’s instructions.                              tion.
             R905.12 Thermoset single-ply roofing. The installation of  R905.15.1  Slope.  Liquid-applied  roofing  shall  have  a
             thermoset single-ply roofing shall comply with the provisions  design slope of not less than one-fourth unit vertical in 12
             of this section.                                        units horizontal (2-percent slope).

             2018 INTERNATIONAL RESIDENTIAL CODE ®                                                               443
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.