APPENDIX H

                                                    PATIO COVERS




                 The provisions contained in this appendix are not mandatory unless specifically referenced in the adopting ordinance.
             User note:
                About this appendix: Appendix H relaxes certain provisions contained in the body of the code as related to patio covers, including those
                regarding: permitted uses; exterior wall insect screens; glazing and translucent or transparent plastic; light, ventilation and emergency egress;
                height; structural design loads; and  footings.  This appendix  also  includes provisions that  are  specifically  applicable to hurricane-prone
                regions.



                              SECTION AH101                                        SECTION AH104
                                 GENERAL                                               HEIGHT
             AH101.1 Scope. Patio covers shall conform to the require-  AH104.1 Height. Patio covers are limited to one-story struc-
             ments of Sections AH101 through AH106.               tures not exceeding 12 feet (3657 mm) in height.
             AH101.2  Permitted  uses.  Patio  covers  detached  from  or
             attached to dwelling units shall be used only for recreational,
             outdoor living purposes, and not as carports, garages, storage        SECTION AH105
             rooms or habitable rooms.                                       STRUCTURAL PROVISIONS
                                                                  AH105.1 Design loads.  Patio covers shall be designed and
                                                                  constructed to sustain, within the stress limits of this code, all
                              SECTION AH102                       dead loads plus a vertical live load of not less than 10 pounds
                                DEFINITION                        per square foot (0.48 kN/m ), except that snow loads shall be
                                                                                        2
             AH102.1 General. The following word and term shall, for  used where such snow loads exceed this minimum. Such cov-
             the  purposes  of  this  appendix,  have  the  meaning  shown  ers shall be designed to resist the minimum wind loads set
             herein.                                              forth in Section R301.2.1.
             PATIO COVER. A structure with open or glazed walls that  AH105.2 Footings. In areas with a frostline depth of zero as
             is  used  for  recreational,  outdoor  living  purposes  associated  specified in Table R301.2(1), for patio covers supported on a
             with a dwelling unit.                                slab-on-grade without footings, the slab shall conform to the
                                                                  provisions of Section R506, shall be not less than 3.5 inches
                                                                  (89  mm)  thick  and  the  columns  shall  not  support  live  and
                              SECTION AH103                       dead loads in excess of 750 pounds (3.34 kN) per column.
                     EXTERIOR WALLS AND OPENINGS
             AH 103.1 Enclosure walls.  Enclosure walls shall be permit-
             ted  to  be  of  any  configuration,  provided  that  the  open  or   SECTION AH106
             glazed area of the longer wall and one additional wall is not  SPECIAL PROVISIONS FOR ALUMINUM SCREEN
             less than 65 percent of the area below 6 feet, 8 inches (2032  ENCLOSURES IN HURRICANE-PRONE REGIONS
             mm) of each wall, measured from the floor. Openings shall  AH106.1  General.  Screen  enclosures  in  hurricane-prone
             be enclosed with any of the following:               regions shall be in accordance with the provisions of this sec-
               1. Insect screening.                               tion.
               2. Approved  translucent  or  transparent  plastic  not  more  AH106.1.1 Habitable spaces. Screen enclosures shall not
                  than 0.125 inch (3.2 mm) in thickness.             be considered habitable spaces.
               3. Glass conforming to the provisions of Section R308.  AH106.1.2 Minimum ceiling  height. Screen enclosures
                                                                     shall have a ceiling height of not less than 7 feet (2134
               4. Any combination of the foregoing.                  mm).
             AH103.2 Light, ventilation and emergency egress.  Exte-  AH106.2 Definition. The following word and term shall, for
             rior openings required for light and ventilation into a patio  the  purposes  of  this  appendix,  have  the  meaning  shown
             structure conforming to Section AH101 shall be unenclosed  herein.
             where  such  openings  serve  as  emergency  egress  or  rescue
             openings from sleeping rooms. Where such exterior openings  SCREEN  ENCLOSURE.  A  building  or  part  thereof,  in
             serve as an exit from the dwelling unit, the patio structure,  whole or in part self-supporting, and having walls of insect
             unless unenclosed, shall be provided with exits conforming to  screening, and a roof of insect screening, plastic, aluminum
             the provisions of Section R311 of this code.         or similar lightweight material.