APPENDIX S



         AS106.13  Braced  wall  panels.  Plastered  strawbale  walls  3. Sill plates shall be not less than nominal 2-inch by 4-
         used as braced wall panels for one-story buildings shall be in  inch (51 mm by 102 mm) with anchoring complying
         accordance with Section R602.10 and Tables AS106.13(1),   with Section R403.1.6.
         AS106.13(2) and AS106.13(3). Wind design criteria shall be  4. Mesh attached with staples at 4 inches (51 mm) on cen-
         in accordance with Section R301.2.1. Seismic design criteria  ter shall be considered to be capable of resisting uplift
         shall be in accordance with Section R301.2.2.             forces of 100 plf (1459 N/m) for each plaster skin.
           AS106.13.1 Bale wall thickness. The thickness of straw-  5. Mesh attached with staples at 2 inches (51 mm) on cen-
           bale braced wall panels without their plaster shall be not  ter shall be considered to be capable of resisting uplift
           less than 15 inches (381 mm).                           forces of 200 plf (2918 N/m) for each plaster skin.
           AS106.13.2 Sill plates. Sill plates shall be in accordance  AS106.15 Post-and-beam with  strawbale infill. Post-and-
           with Table AS106.13(1).                            beam  with  strawbale  infill  systems  shall  be  in  accordance
           AS106.13.3 Sill plate fasteners. Sill plates shall be fas-  with Figure AS105.1(4) and Items 1 through 6, or be of an
                               5
           tened with not less than  / -inch-diameter (15.9 mm) steel  approved engineered design.
                                8
                                           3
           anchor bolts with 3-inch by 3-inch by  / -inch (76.2 mm  1. Beams shall be of the dimensions and number of mem-
                                            16
           by 76.2 mm by 4.8 mm) steel washers, with not less than  bers  in  accordance  with  Table  R602.7(1),  where  the
           7-inch (177.8 mm) embedment in a concrete or masonry    space between posts equals the span in the table.
           foundation, or shall be an approved equivalent, with the                                           1
           spacing  shown  in  Table  AS106.13(1).  Anchor  bolts  or  2. Beam  ends  shall  bear  over  posts  not  less  than  1 / 2
           other fasteners into framed floors shall be of an approved  inches (38 mm) or be supported by a framing anchor in
           engineered design.                                      accordance with Table R602.7(1).
         AS106.14 Resistance to wind uplift forces. Plaster mesh in  3. Discontinuous beam ends shall be spliced with a metal
         skins of strawbale walls that resist uplift forces from the roof  strap with not less than 1,000-pound (454 kg) wind or
         assembly, as determined in accordance with Section R802.11,  seismic  load  tension  capacity.  Where  the  wall  line
         shall be in accordance with all of the following:         includes a braced wall pane,l the strap shall have not
                                                                   less than a 4,000-pound (1814 kg) capacity.
           1. Plaster shall be any type and thickness allowed in Sec-
              tion AS104.                                        4. Each post shall equal NJ + 1 in accordance with Table
                                                                   R602.7(1),  where  the  space  between  posts  equals the
           2. Mesh shall be any type allowed in Table AS106.13(1),  span in the table.
              and shall be attached to top plates or roof-bearing ele-
              ments  and  to  sill  plates  in  accordance  with  Section  5. Posts shall be connected to the beam by an approved
              AS106.9.2.                                           means.
                                                                 6. Roof and ceiling framing shall be attached to the beam
                                                                   in accordance with Table R602.3(1), Items 2 and 6.


                                                     TABLE AS106.13(1)
                                      PLASTERED STRAWBALE BRACED WALL PANEL TYPES
                               PLASTER  (both sides)             b             c
                                      a
              WALL                         Thickness    SILL PLATES  ANCHOR BOLT       MESH d         STAPLE  e
                                                                       SPACING
                                                                                                     SPACING
           DESIGNATION       Type       (minimum in inches   (nominal size in   (inches on center)  (inches)  (inches on center)
                                                          inches)
                                           each side)
               A1            Clay            1.5           2  4          32            None           None
                                                                                   2  2 high-density
               A2            Clay            1.5           2    4        3  2                          2
                                                                                    polypropylene
               A3            Clay            1.5           2    4        3  2     2      2  14 gage  4
                B          Soil-cement        1            4    4        2  4     2      2  14 gage  2
               C1            Lime            7 / 8         2  4          32      17-gage woven wire    3
               C2            Lime            7 / 8         4    4        2  4     2      2  14 gage  2
               D1         Cement-lime        7 / 8         4  4          32      17 gage woven wire    2
               D2         Cement-lime        7 / 8         4    4        2  4     2      2  14 gage  2
               E1           Cement           7 / 8         4    4        3  2     2      2  14 gage  2
               E2           Cement           1.5           4    4        2  4     2      2  14 gage  2
         SI: 1 inch = 25.4 mm.
         a. Plasters shall comply with Sections AS104.4.3 through AS104.4.8, AS106.7, AS106.8 and AS106.12.
         b. Sill plates shall be Douglas fir-larch or southern pine and shall be preservative treated where required by the International Residential Code.
         c. Anchor bolts shall be in accordance with Section AS106.13.3 at the spacing shown in this table.
         d. Installed in accordance with Section AS106.9.
         e. Staples shall be in accordance with Section AS106.9.2 at the spacing shown in this table.