Modernfold GWS PureView Technical Data
®
10 22 26 Operable Partitions
MOVABLE GLASS WALL TECHNICAL DATA
7. RAL “Classic” (Solids collection) Powder Coat remove dust, loose fibers, fingerprints, adhesives,
available (Sherwin Williams’ Powdura Super and other foreign materials according to
Durable TGIC Free Polyesters) provided in one manufacturer’s written instructions.
of the following (select one): B. Provide final protection and maintain conditions
a. Gloss finish (80°-85° gloss) in a manner acceptable to manufacturer and
b. Satin finish (30° gloss) Installer that insure operable glass partitions
are without damage or deterioration at time of
2.6 SUSPENSION SYSTEM Substantial Completion.
A. G-330 Suspension System
1. Suspension Tracks: Extruded aluminum with 3.3 ADJUSTING
a minimum wall thickness of 0.235 inches (6 A. Adjust operable glass partition to operate
mm). Incorporate cast aluminum or mitered smoothly, easily, and quietly, free from
intersections, switches, and curves in stacking binding, warp, excessive deflection, distortion,
area. Provide alignment pins for track, nonalignment, misplacement, disruption, or
intersections, switches and curves insuring both malfunction, throughout entire operational range.
fit and roller surface integrity. Lubricate hardware and other moving parts.
a. Exposed track soffit: Factory-finished
aluminum with white powder coat. 3.4 EXAMINATION
2. Carriers: Two stainless steel trolleys with vinyl A. Examine flooring, structural support, and
roller surfaces. Trolley design incorporates eight opening, with Installer present, for compliance
(8) wheels of varying dimensions. Automatic with requirements for installation tolerances
indexing of panels into stack area is provided and other conditions affecting performance of
by pre-programmed switches and trolleys operable glass partitions. Proceed with installation
without electrical, pneumatic, or mechanical only after unsatisfactory conditions have been
activation. corrected.
1. Insure finished floor under operable glass
2.7 OPTIONS partition is level ± 0.13-inch (3 mm) in ten (10)
A. Door pulls back-to-back feet (3048 mm) non-cumulative.
1. 12” tubular pull
2. Manet 1240mm “Ladder Pull” 3.5 DEMONSTRATION
3. TG-138 49” locking “Ladder Pull” A. Demonstrate proper operation and maintenance
B. Automatic door closer procedures to Owner’s representative.
1. BTS80 floor closer B. Provide Operation and Maintenance Manual to
2. RTS88 ceiling closer Owner’s representatives.
PART 3 EXECUTION
3.1 INSTALLATION
A. General: Comply with ASTM E557, operable
glass partition manufacturer’s written installation
instructions, Drawings, and approved Shop
Drawings.
B. Install operable glass partitions and accessories
after other finishing operations, including painting,
have been completed.
C. Match operable glass partitions by installing
panels from marked packages in numbered
sequence indicated on Shop Drawings.
D. Broken, cracked, chipped, deformed, or
unmatched panels are not acceptable.
3.2 CLEANING AND PROTECTION
A. Clean metal and glass surfaces upon completing
installation of operable glass partitions to