Variable Area Rota Meters
                                                                     Types : Acrylic Body, Glass Tube, Metal Tube, Bye-Pass Type
                                                                     Size : 1/4” ~ 20”
                                                                     Accuracy : ± 2% of FSD
                                                                     Accessories : Built in Needle Valve, Digital Indicator,
                                                                     Transmitter with 4 - 20 mA output
                                                                     Service : Water, Air, Oil, Gases, Chemicals, Milk, Solvents
                                                                     End Connections : Screwed, Flanged, Tri-clover, SMS Union


                                                                    Woltmann type Water Flow Meters
     Size : ½” ~ 20”
     Accuracy : ± 2% of FSD
                          O                 O
     Service : Cold Water up-to 50 C & Hot Water up-to 130 C
     End Connections : Screwed, Flanged as per PN 10/16
     Wide Range (Turn-down Ratio) : 107:1 (Qmin to Qmax)
     Approval : EEC/ISO 4064
     Communication : Pulse output, M-Bus Protocol,
     Radio Frequency wireless Link
     Accessories : Remote Display, Hand Held Reader

     S.S. Construction Turbine Flow Meters
                                                                     Size : ½” ~ 20”
                                                                     Accuracy : ± 1% of FSD
                                                                     Service : Clear Liquids, Gases, Air, Solvents etc
                                                                     End Connections : Screwed, Flanged as per PN 10/16
                                                                                    O
                                                                     Maximum Temp. : 150 C
                                                                     Options : Flow Rate Indicator / Totaliser / Transmitter / Controller
                                                                     in Local / Remote Panel / Pr. - Temp Compensation
                                                                     Out-put : Pulse / 4-20 mA / Relay
                                                                                    3
                                                                     Calibration : Litres, m , Kg etc
                                                                     Mounting : In Line / Insertion
                                                                           Electromagnetic Flow Meters
     Size : ½” ~ 20”
     Accuracy : ±  0.5 % of FSD
     Service : Raw Water, ETP Water, Dirty Liquid
     End Connections : Flanged as per PN 10/16                                          MAGNETIC FLOW METER
                    O
     Maximum Temp. : 150 C (Subject to Lining Material)
     Lining Options : Neoprene, PTFE, Hard Rubber
                                                                                         IOTAFLOW
     Out-put : Pulse / 4-20 mA / Relay / RS 485                                        AFLOWT-MF  SYSTEMS PVT. LTD
     Feature : No Moving Part
     Display : Local / Remote
     Mounting : In Line / Insertion
     Ultrasonic Flow Meters - Portable / Fixed

                                                 Measurement Technology: Ultrasonic Transit Time Correlation Principle and Doppler
                                                 Flow velocity:  (0.01....25) m/s
                                                 Resolution:   0.025 cm/s
                                                 Repeatability:  0.25% of reading ±  0.02 m/s
                                                 Accuracy:     (for fully developed, rotationally symmetrical flow profile)
                                                 - Volume flow  ±  1%....3% of reading / ±  0.02m/s depending on application
                                                               ±  0.5% of reading / ±  0.02m/s with process calibration
                                                 Measurable fluids: All sonically conductive fluids with <10% gaseous or solid content in
                                                 volume
                                                 Recommended pipe measuring range: 1” ~ 40”
                                                 Models available:  Portable / Fixed