Page 86 - Pricelist
P. 86

GAS CHROMATOGRAPH SYSTEM





























                                                 CAT. NO.: BE/CI/GC/01
                                                   PRICE: ` 6,20,000/-



            FEATURES

            • Microprocessor based control system                signals, such as automatic sampling device,
            • Synchronous bidirectional control with touch screen    thermal analyzer and so on.
            • 7-Inch color touch screen for easy monitoring of   • The instrument is equipped with automatic
              flow rate and pressure value                       self-checking function and malfunction detection
            • The multi-core, 32-bit embedded hardware system     system coupled with alarm system.
              ensures the reliable operation of the instrument   • The machine has 8 external event interfaces with
            • One key start-up function                           extendable functions which can work with a
            • The memory function can store 20-sample test        variety of functional control valve performing
               modes                                              according to the set timing.
            • The extendable synchronous external trigger      • RS232 communication port and LAN port.
              function can initiate workstation through external





            TECHNICAL SPECIFICATIONS

            OVEN                                              SAMPLE INJECTOR

            • Inside capacity 22 L                            • Temperature range: room temperature up
            • Temperature range: room temperature up             7 °C – 420 °C
               5 °C – 400 °C                                  • Temperature control type: independent
            • Temperature accuracy: ± 0.1 °C                  • Carrier gas flow control type: constant pressure
            • Temperature programming: 9 steps                • Max quantity: 3PCS
            • Program total time: 9999.9 min                  • Type: Packed column or split
            • Max heating rate: 0.1 – 60 °C/min               • Split ratio: Display
            • Max cooling rate: ≤ 10 mins (250 °C - 50 °C)    • Pre-Column pressure range: 0 – 400kPa
                                                              • Pre- column pressure accuracy: 0.1 kPa
                                                              • Flow setting range:    H2: – 0 - 200 ml/min
                                                                                    N2: – 0 - 150ml/min




         86                                  BioEra Life Sciences Pvt. Ltd.  |  www.bioera.in
   81   82   83   84   85   86   87   88   89   90   91