Page 86 - NAME OF CONDITION: REFRACTIVE ERRORS
P. 86
1. Bird AC, Bressler NM, Bressler SB, Chisholm IH, Coscas G, Davis MD, et al. An
international classification and grading system for age-related maculopathy and age-
related macular degeneration. The International ARM Epidemiological Study Group
[Internet]. Survey of Ophthalmology. 1995 ;39(5):367-374.Available from:
http://www.ncbi.nlm.nih.gov/pubmed/7604360
2. Krishnaiah S, Das T, Nirmalan PK, Nutheti R, Shamanna BR, Rao GN, et al. Risk factors
for age-related macular degeneration: findings from the Andhra Pradesh eye disease
study in South India [Internet]. Investigative Ophthalmology & Visual Science. 2005
;46(12):4442-4449.Available from: http://www.ncbi.nlm.nih.gov/pubmed/16303932
3. Nirmalan PK, Katz J, Robin AL, Tielsch JM, Namperumalsamy P, Kim R, et al.
Prevalence of vitreoretinal disorders in a rural population of southern India: the
Aravind Comprehensive Eye Study. [Internet]. Archives of ophthalmology. 2004
;122(4):581-6.Available from: http://www.ncbi.nlm.nih.gov/pubmed/15078677
RESOURCES REQUIRED
Situation HUMAN INVESTIGATIONS DRUGS & EQUIPMENT
RESOURCES CONSUMABLES
1) 1)Ophthalmologist - 1 1)Amsler grid 1)Dilating drops 1)Slit lamp
Secondary 2)OP Nurse – 1 2)Fundus 2)Fluorescein dye 2)90 D lens
level 3)Refraction nurse - 1 fluorescein 3) Needles and 3)20 D lens
4)FFA technician-1 angiography syringes 4)Indirect
(optional) 5)ophthalmoscope
Fundus camera
2)Tertiary 1)Ophthalmologist - 1 1)FFA 1)Dilating drops 1)Slit lamp
level 2)OP Nurse – 2 2)OCT 2 Fluorescein dye 2)90 D lens
3)Refraction nurse - 1 3)ICGA ICG dye 3)20 D lens
4)FFA technician-1 3)Anti VEGF 4)Indirect
injections 5)Ophthalmoscope
4) Needles and 6)Fundus camera
syringes 7)OCT machine
5) Suture materials 8) Laser
equipment
9) Operating
microscope
86