Page 64 - ITALVIBRAS E-CATALOG
P. 64

MTF-E

                                               The MTF-E series has been designed for use in industrial
                                               processes in environments with a potentially explosive
                                               atmosphere, caused by gas and dusts, in compliance with
                                               ATEX Directive (94/9/EC).
                                               In particular, the MTF-E series can be used in areas 1 and
                                               2 (gas) and areas 21 and 22 (dusts) according to the layout
                                               and following features:

Technical features

   Power supply                                Protection against thermal protection           The electrical connection must be carried
   Three-phase voltage from 220V to 690V,      IK 08 according to IEC 68, EN 50102.            out using the relative connectors inser-
   50Hz or 60Hz; suitable for use with a                                                       ted inside the connection box.
   PWM inverter from 20Hz to the base fre-     Insulation class                                Special shaped terminals allow to fix the
   quency with constant torque load profile.   Class F (155°C).                                power supply cable, protecting it from
   	                                                                                           loosening.
   Polarity                                    Tropicalization
   2 and 4 poles.                              Standard on all vibrators, with vacuum          Electric motor
                                               encapsulation up to size 30, with “drop         Three-phase asynchronous type. De-
   Conformity with European Directives         by drop” trickle system for larger sizes.       signed for maximum starting torques
   Low Voltage 2006/95/EC,                                                                     and torque curves adapt for the specific
   ATEX 94/9/EC.                               Ambient temperature                             requirements of vibrating machines.
   	                                           From -20°C to +40°C, on request it is pos-      Insulated windings using vacuum encap-
   Reference Regulations                       sible to have vibrators for max. ambient        sulating up to size 30; using the “drop by
   IEC/EN 60079-0, IEC/EN 60079-7,             temperatures of +55°C.                          drop” trickle system with class H resin
   IEC/EN 60079-31, EN 60034-1.                                                                for sizes 40-50-70. The rotor is die cast
                                               Vibrator thermal protection                     aluminium.
   Controls                                    On demand with PTC rated thermistor heat        		
   The components that affect protection       detectors 130°C (DIN 44081-44082). Also on      Casing
   are 100% accurately controlled and          request thermistors with different tempe-       In high-tensile aluminium alloy up to size
   recorded.                                   ratures and anti-condensation heaters.	         50, in spheroidal cast iron for size 70.
                                                                                               An external earthing screw is located on
   Functioning                                 Fixing of the vibrator                          the casing as prescribed by Regulation
   Continual service (S1) at maximum decla-    In all positions and therefore without          IEC/EN 60079-0
   red centrifugal force and electric power.   restriction.	                                   	
                                                                                               Bearing flange
   Centrifugal force                           Lubrication                                     Constructed in cast iron (ductile or grey)
   Range extended up to 2615 Kgf. (25.7 KN),   All vibrators are lubricated in the factory     or in aluminium with steel bearing seat.
   with centrifugal force adjustable from 0    and do not require further lubrication if       The geometry of the flange transmits the
   to 100%.                                    used in normal operating conditions. In         load to the casing uniformly.
                                               heavy duty operating conditions perio-
   Mechanical protection                       dical re-lubrication may be applied to       N
   IP 66 according to IEC 529, EN 60529;       frame sizes 40-50-70.
   mechanical protection is ensured in the     	                                               Bearings
   mounting phase of the vibrator onto the     Electrical connection box                       The lower and upper bearings have been
   vibrating machine, by introducing the       The size guarantees passage of tools            studied to support the relative load and
   special seal into the seat on the coupling  used for fixing the vibrator to the vibra-      therefore they have a particular geome-
   flange.                                     ting machine.                                   try, especially designed and made for
                                                                                               Italvibras.
64                                                                                             	

                                                                                               B

                                                                                            H