MTF-E
The MTF-E series has been designed for use in industrial
processes in environments with a potentially explosive
atmosphere, caused by gas and dusts, in compliance with
ATEX Directive (94/9/EC).
In particular, the MTF-E series can be used in areas 1 and
2 (gas) and areas 21 and 22 (dusts) according to the layout
and following features:
Technical features
Power supply Protection against thermal protection The electrical connection must be carried
Three-phase voltage from 220V to 690V, IK 08 according to IEC 68, EN 50102. out using the relative connectors inser-
50Hz or 60Hz; suitable for use with a ted inside the connection box.
PWM inverter from 20Hz to the base fre- Insulation class Special shaped terminals allow to fix the
quency with constant torque load profile. Class F (155°C). power supply cable, protecting it from
loosening.
Polarity Tropicalization
2 and 4 poles. Standard on all vibrators, with vacuum Electric motor
encapsulation up to size 30, with “drop Three-phase asynchronous type. De-
Conformity with European Directives by drop” trickle system for larger sizes. signed for maximum starting torques
Low Voltage 2006/95/EC, and torque curves adapt for the specific
ATEX 94/9/EC. Ambient temperature requirements of vibrating machines.
From -20°C to +40°C, on request it is pos- Insulated windings using vacuum encap-
Reference Regulations sible to have vibrators for max. ambient sulating up to size 30; using the “drop by
IEC/EN 60079-0, IEC/EN 60079-7, temperatures of +55°C. drop” trickle system with class H resin
IEC/EN 60079-31, EN 60034-1. for sizes 40-50-70. The rotor is die cast
Vibrator thermal protection aluminium.
Controls On demand with PTC rated thermistor heat
The components that affect protection detectors 130°C (DIN 44081-44082). Also on Casing
are 100% accurately controlled and request thermistors with different tempe- In high-tensile aluminium alloy up to size
recorded. ratures and anti-condensation heaters. 50, in spheroidal cast iron for size 70.
An external earthing screw is located on
Functioning Fixing of the vibrator the casing as prescribed by Regulation
Continual service (S1) at maximum decla- In all positions and therefore without IEC/EN 60079-0
red centrifugal force and electric power. restriction.
Bearing flange
Centrifugal force Lubrication Constructed in cast iron (ductile or grey)
Range extended up to 2615 Kgf. (25.7 KN), All vibrators are lubricated in the factory or in aluminium with steel bearing seat.
with centrifugal force adjustable from 0 and do not require further lubrication if The geometry of the flange transmits the
to 100%. used in normal operating conditions. In load to the casing uniformly.
heavy duty operating conditions perio-
Mechanical protection dical re-lubrication may be applied to N
IP 66 according to IEC 529, EN 60529; frame sizes 40-50-70.
mechanical protection is ensured in the Bearings
mounting phase of the vibrator onto the Electrical connection box The lower and upper bearings have been
vibrating machine, by introducing the The size guarantees passage of tools studied to support the relative load and
special seal into the seat on the coupling used for fixing the vibrator to the vibra- therefore they have a particular geome-
flange. ting machine. try, especially designed and made for
Italvibras.