Page 16 - QR IMER STEP120
P. 16

~~  IMER  INTERNATIONAL                                                  S.p.A.
                       STEP 120

When the two sponges are delivered from the hose, washing is

complete.

- At this point, on completion of machine cleaning, turn off the

main switch, and disconnect the power plug,


If there is any risk of freezing, open the hopper plug, disconnect

the pipelines and drain all water from the circuit (fig.11).


      /
                                                                        \
     !
                                                                          \

        \                                                                    \ '"".----------.---­
                                                                                                            FIG 12
      \
                                                                         15. MIXER
    -".\ ,/
                                                                         The mixer is available as an optional accessory both for the 3­
           " ./                                                          phase and single phase versions. The technical specifications
                                                                         are provided in table 1, page 3. It must be connected by means
                  ""'---------.-----'                                    of a plug to the electrical panel.
                                                                         It is activated by means of switch (ref. 1, fig13); when this is
                                  FIG 11                                 turned from one position to the other, the blades start to rotate in
                                                                         the working direction or the opposite direction. The correct
ill - Before opening the drain plug or removing the                      direction of rotation for work is as shown in figure 13.

grid, ensure that the main switch is turned to 0 and the                 ill - CAUTION! All devices must be correctly fixed be­
plug is disconnected from the power supply
                                                                         fore machine start-up.

14. MAINTENANCE                                                                  FIG 13

& - Maintenance must be performed by adequately

trained personnel, after switching off the machine, dis­

connecting it from the power supply and emptying the

hopper.

-Lubricate with grease daily via the hole in figure 12

Check weekly that the compressor air filter is clean. If deterio­

rated, replace.

Check weekly that the electric motors are free of dust and dirt

and if necessary clean using compressed air.

Check weekly that the plug and socket contacts are clean, dry

and rust free.

Every six months arrange for an inspection of the machine by an

authorised IMER service centre.


&, - Spent oil is a special waste. Therefore it must be

disposed of according to current legislation.

&, - Always keep notices and symbols on the machine

legible.

15. REPAIRS

&, - Never start up the plastering machine during re­

pairs.
Repairs to the electrical installation must be performed exclu­

sively by specialised personnel.

I Use exclusively original IMER spare parts; modifications

to parts are strictly prohibited.


& -If any guards are removed for repairs, ensure they

are refitted correctly at the end of work.

                                                                     30