Page 16 - QR IMER STEP120
P. 16
~~ IMER INTERNATIONAL S.p.A.
STEP 120
When the two sponges are delivered from the hose, washing is
complete.
- At this point, on completion of machine cleaning, turn off the
main switch, and disconnect the power plug,
If there is any risk of freezing, open the hopper plug, disconnect
the pipelines and drain all water from the circuit (fig.11).
/
\
!
\
\ \ '"".----------.---
FIG 12
\
15. MIXER
-".\ ,/
The mixer is available as an optional accessory both for the 3
" ./ phase and single phase versions. The technical specifications
are provided in table 1, page 3. It must be connected by means
""'---------.-----' of a plug to the electrical panel.
It is activated by means of switch (ref. 1, fig13); when this is
FIG 11 turned from one position to the other, the blades start to rotate in
the working direction or the opposite direction. The correct
ill - Before opening the drain plug or removing the direction of rotation for work is as shown in figure 13.
grid, ensure that the main switch is turned to 0 and the ill - CAUTION! All devices must be correctly fixed be
plug is disconnected from the power supply
fore machine start-up.
14. MAINTENANCE FIG 13
& - Maintenance must be performed by adequately
trained personnel, after switching off the machine, dis
connecting it from the power supply and emptying the
hopper.
-Lubricate with grease daily via the hole in figure 12
Check weekly that the compressor air filter is clean. If deterio
rated, replace.
Check weekly that the electric motors are free of dust and dirt
and if necessary clean using compressed air.
Check weekly that the plug and socket contacts are clean, dry
and rust free.
Every six months arrange for an inspection of the machine by an
authorised IMER service centre.
&, - Spent oil is a special waste. Therefore it must be
disposed of according to current legislation.
&, - Always keep notices and symbols on the machine
legible.
15. REPAIRS
&, - Never start up the plastering machine during re
pairs.
Repairs to the electrical installation must be performed exclu
sively by specialised personnel.
I Use exclusively original IMER spare parts; modifications
to parts are strictly prohibited.
& -If any guards are removed for repairs, ensure they
are refitted correctly at the end of work.
30