Page 48 - combinepdf
P. 48

Auckland Council                                                                                 Utilities and Underground Services               Legend



         Stormwater                                            Water                               Wastewater                          Utilities


         Note: Unless otherwise specified in the text below, the colour  3  Valve                    !     Fitting                             Transpower Site
         of a Stormwater symbol is determined by the ownership or                                    !     Fitting (Non Watercare )
         useage status, using the following colour scheme:        (    Hydrant                                                           S     Pylon (Transpower)








              ,





                        Abandoned







         Public Private  or                                                                          ! ! ! !  Manhole                          110 kv - Electricity








                                                                  !    Fitting
                                                                                                           Pipe (Non Watercare)                Transmission
                                                                  !    Other Watercare Point Asset
           T  %  Treatment Device       Overland Flowpath                                                  Local Pipe (Main / Service          220 kv - Electricity
                                        (Public)                       Other Watercare Linear              Line)                               Transmission
          ! S   Septic Tank             Overland Flowpath              Asset                               Local Pipe (Abandoned)              400 kv - Electricity
          !     Septic Tank (Hi-Tech)   (Private)                      Local Pipe (Bulk)                   Local Pipe (Future)                 Transmission
           HT
                                        Forebay (Public)                                                                                       Aviation Jet A1 Fuel Pipeline
           ! <  Soakage System                                         Local Pipe (In Service)             Transmission Pipe (In
                                        Forebay (Private)              Local Pipe (Abandoned)              Service)                            Liquid Fuels Pipeline
           ! (  Inspection Chamber                                                                                                             [Marsden to Wiri]
                                        Treatment Facility                                                 Transmission Pipe (Out Of
                Manhole (Standard /                                    Transmission Pipe (In               Service)
           ! R                          (Public)                                                                                               Gas Transmission Pipeline
                Custom)                                                Service)                            Transmission Pipe
           @    Inlet & Outlet Structure  Treatment Facility           Transmission Pipe (Out of           (Proposed)                          High-Pressure Gas Pipeline
                                        (Private)
                                                                       Service)
                Inlet & Outlet (No  P S P S P S  Pump Station          Transmission Pipe                   Chamber                             Medium-Pressure Gas
            Ø
                Structure)     P S P @ @ @ S                           (Proposed)                          Structure (Non Watercare)           Pipeline
                                   S P @ @@
           ¢ D  Catchpit          @ @ @ @ @ @ @ @ @@ Planting          Pump Station                                                            Indicative Steel Mill Slurry
                                   @  @                                                                    Pump Station                        Pipeline
                                        Embankment
                Spillway                                               Reservoir                           Wastewater Catchment
                                        Viewing Platform                                                                                       Indicative Steel Mill Water
                Safety Benching                                        Other Structure (Local)                                                 Pipeline
                                        Bridge                                                                                                 Fibre Optic Cable (ARTA)
                Culvert / Tunnel
                                        Erosion & Flood Control        Chamber (Transmission)
                Subsoil Drain           (Other Structure)                                                                                      Contour Interval
                                                                       Water Source (Transmission)
                Gravity Main            Erosion & Flood Control
                                        (Wall Structure)               Other Watercare Structures
                Rising Main                                            and Areas
                Connection
        D  D  D Fence
                Lined Channel
                Watercourse
                                                                                                                                        Legend
                                                                                                                                        updated:
                                                                                                                                       15/08/2019
   43   44   45   46   47   48   49   50   51   52   53