Page 8 - TEST_QUIRURGICAS_Neat
P. 8
Page 7 of 16 Ref. No.: PPE-20200015
EN 149: 2001 + A1: 2009
Clause Requirement – Test Result - Remark Verdict
wearer shall have no sharp edges or burrs.
7.9 Leakage P
7.9.1 Total inward leakage P
The laboratory tests shall indicate that the particle filtering
half mask can be used by the wearer to protect with high P
probability against the potential hazard to be expected.
The total inward leakage consists of three components:
face seal leakage, exhalation valve leakage (if exhalation
valve fitted) and filter penetration. P
For particle filtering half masks fitted in accordance with
the manufacturer’s information.
Total inward leakage shall be not greater than:
25% for FFP1
20.1% P
11% for FFP2
5% for FFP3
Penetration of filter material
For FFP1
Sodium chloride test 95 l/min % max. 20
Paraffin oil test 95 l/min % max. 20
For FFP2 Sodium chloride: 17.7%
7.9.2 Paraffin oil: 16.5% P
Sodium chloride test 95 l/min % max. 6
Paraffin oil test 95 l/min % max. 6
For FFP3
Sodium chloride test 95 l/min % max. 1
Paraffin oil test 95 l/min % max. 1
The penetration of the filter of the particle filtering half
P
mask shall meet the requirements.
7.10 Compatibility with skin P
Materials that may come into contact with the wearer’s
skin shall not be known to be likely to cause irritation or P
any other adverse effect to health.
7.11 Flammability P
The material used shall not present a danger for the
No burn. P
wearer and shall not be of highly flammable nature.
7.12 Carbon dioxide content of the inhalation air P
The carbon dioxide content of the inhalation air (dead
The carbon dioxide: 0.66% P
space) shall not exceed an average of 1.0 % (by volume).
7.13 Head harness P
The head harness shall be designed so that the particle The head harness is
P
filtering half mask can be donned and removed easily. adjustable.
7.14 Field of vision P