Page 25 - 2020 7th St Presentation
P. 25
Pool Coping Detail Pool Coping Detail Spa Section Spa Section
A1 Scale: 1" = 1'-0" Provide Option for Square Coping A2 Scale: 1" = 1'-0" B1 Scale: 1/2" = 1'-0" B2 Scale: 1/2" = 1'-0"
L:\21-134 Toscana 2231 Forrest Lane\ALD-Dwgs\21-134.dwg, Plotted on 9/12/2021 10:24:40 PM by Christian Andrea
Provide option for Stone Coping 7'-4" 8'-8"
Schluter Drain Material 1'-6" 5' 10" 10" 1'-6" 4' 1'-6" 10"
1
1
1
1
Stone Deck TBD 1 - 1 Thick Planter 1 - 1 Thick 1-1/2" Sand Set Stone Deck
4"
4"
2"
2"
Stone Coping TBD Stone Coping TBD 3 LANDSCAPE ARCHITECTURE
1"+/- Mortar 1" Sand Angle Top of Wall " Angle Top of Wall " Angle Top of Wall "
3
3
4
1' 1' Waterline 4 Waterline 4
4" 2780 S. Horseshoe Drive Suite 5
6" Naples, FL 34104
4 1 " 2 Water Surface Water Surface (239) 430-1661
1'-8" Tile (Opt.) 1'-8"
4" Compacted Limerock Design@ALDinc.net
4" Concrete Slab w/ 6" Waterline Tile 6" Waterline Tile Light
6"x6" 10 gau. Welded Pebblecrete Finish Pebblecrete Finish 3'-6" Pool Pool Steps 3'-6" Pool Steps License LC26000259
Wire Mesh or Fibercrete Vent Vent
1'-6" Drain Drain 1'-6" Christian Andrea
Pool Beam Pool Beam
3.5' Water Depth 3.5' Water Depth
Compact subgrade 95%
Optimum Proctor Density
Compact subgrade 95% License No. 1178
Optimum Proctor Density
Copyright Architectural Land Design ©
Pool Stairs Detail Pool Bench Detail Fountain Emitter Detail
C Scale: 1" = 1'-0" D Scale: 1" = 1'-0" E Scale: 1" = 1'-0"
Model: RPWJ-DFJ
3'-6"
Throw
Provide option for 1 1 Fountain Emitter stainless steel
2"
4"
Schluter Drain Material Provide option for 1 - 1 Thick 1/2"-3/8" valved separately
Stone Deck TBD Stone Coping Schluter Drain Material Stone Coping TBD Must shoot 3'-0' from coping.
1"+/- Mortar Stone Deck TBD 6" Pool Tile
1"+/- Mortar Apex Pool Coping
6" Pool Tile 1' 1 1 " 2 60° 1' Waterstop Flange
4 1 " 2 Water Surface
9" 4 1 " 2 Water Surface
4 1 " 2 5"
Pool Finish Water Surface 6" 2231 Forrest Lane 2231 Forrest Ln. City of Naples, FL POOL DETAILS
4" Concrete Slab w/ Pool Bench - 18" Water Depth 30° 3/4" PVC (Socket)
authorization. Any deviations or inaccuracies need to be brought to the attention of the Owner immediately. * All base information has been provided by others, verification of setbacks, property lines, etc. need to be provided by others. * It is the Contractors responsibility to verify that he has the most current plan. * Contractor shall not scale from plan, use dimensions only. * These plans are the property of Architectural Land Design and may not be used or reproduced without This Document contains information proprietory to ARCHITECTURAL LAND DESIGN and no part of this drawing shall be reproduced or disclosed to others or used for any purpose other than that for which it was furnished, without prior written permission from ARCHITECTURAL LAND DESIGN. Pool Beam 1' Wire Mesh or Fibercrete 1'-6" 2" 2" Pool Finish Supply Connection
9"
Pebblecrete finish (TBD)
6"x6" 10 gau. Welded
6" Pool Tile
Pool Beam NOTE:
9" A 1/2" x 1/4" Reducer & Short
3'-6" POOL Included for you use in Connecting
1' Piece of 1/4" PVC Pipe are
Concrete Pool Beam the Deck Jet Drain, if Needed.
9 1 " 2 2" Strip of Tile TECHNICAL AND HYDRAULIC DATA
1' at Edge of Bench PVC THROW @ 60° ANGLE
MODEL SLIP DISTANCE 3' 4' 6' 8'
(FAN JET) NOZZLE MAX. APEX @ 60° 14" 20" 34" 52"
Compact Sub grade 95% RPWJ-DFJ 3/4" GPM 1.5 2.0 2.5 3.5
SPREAD 6" 12" 44" 84"
Optimum Proctor Density Pebblecrete NOTE: AN 8" MINIMUM WALL THICKNESS REQUIRED TO INSTALL UNIT.
10" finish (TBD) NOTE: USE ONLY PURPLE PRIMER AND HEAVY BODY GRAY PVC GLUE TO INSTALL. SPECIFICATION DATA: High strength thermoplastic niche body with
waterstop/key flange, rebar attachment holes, adjustable brass fan nozzle,
C COPYRIGHT 2006 ROMAN FOUNTAINS
ALL RIGHTS RESERVED recessed brass cover plate with stainless steel cover fasteners, 3/4" PVC (socket)
supply connection, and 1/2" PVC (ftg) drain connection.
ROMAN FOUNTAINS CORP.
P.O. Drawer 10190
Albuquerque, N.M. 87184 DESIGN/APPLICATION DATA: RPWJ-DFJ Series, fan nozzle deck jets are designed
Phone #: (800) 794-1801 for use in pools where a flush mounted deck nozzle is required. The modular
roman
fountains Fax #: (505) 343-8086 design facilitates ease of installation while providing a clean, unobtrusive, vandal
SM http://www.romanfountains.com
America's Fountain Company! resistant finish.
Typical - Pool Beam Channel Drain
F
Scale: 1" = 1'-0"
Glue Stones Together at Channel Drain Gap to NDS Mini or SPEE-D Channel drain grate Contractor to Verify before Installation
Avoid Stone Movement over Channel Drain with U.V. inhibitor or approved equal NDS Mini
Saw cut the drain (12" long cuts with 6" gaps)
Coping (tbd)
NDS Mini or SPEE-D Channel
Channel Drain - Perspective View Channel Drain - Plan View drain or approved equal 1 2 "
1" +\- Thick Mortar bed
Drawing Date: IS 07.09.21
Provide Option for Schluter Drain Material
Scale: As Noted
1-1/2" Stone Patio 1'
Pool Pool
Pool Deck 21-134
1" 4 1 " 2
Water Surface
6"
Glue Stones Together
at joints adjacent to Channel Drain 4" Concrete Slab w/ 6" Pool Tile
channel drain
6"x6" 10 gau. Welded
Pebblecrete Finish
Wire Mesh or Fibercrete 8"
Pool Beam
Compacted Subgrade
Pool Beam File Name: 21-134.dwg
95% Optimun Proctor Density Bottom Drain End Drain
1
6" Waterline Tile 1 " Thick Stone Coping Adapter Option Adapter Option Architectural Information Provided By:
2
NDS Mini or SPEE-D Channel Drain 1 Channel Drain Company Name: ----
----
File Name:
Pool Beam Pool Decking w/ " gap Date: ----
2
Mud Set Pavers 1 " 2
Pool Deck Slab 1' 1' Site Information Provided By: ----
Company Name:
Compacted Subgrade File Name: ----
6" Date: ----
Saw Cuts within the channel drain grate
1.6
Contractor to verify property lines and setbacks before construction.
Contractor must have property lines staked and located,
and must verify plan dimensions and field conditions are consistent.
Any Inconsistencies w/ these plans need to be reported to ALD and the Owner.
Contractor shall verify that he has the most up to date plans, and that they have
Contractor shall verify that he has the most up to date plans, and that they have been approved and accepted by the Owner before commencing construction. been approved and accepted by the Owner before commencing construction.