Page 72 - DRAGO GT Operators Manual
P. 72

Section 7 – Lubrication/Maintenance

             Row Unit Gearbox

             Every 100 hours of operation inspect the oil level in
             the row unit gearbox. Lower the corn head to
             operating position and remove the dipstick (A) on
             each row. The oil should be between the maximum and
             minimum marks on the dipstick (A).

             Lubricant Type:
                    Mobil SHC 634

             Capacity:
                    Non-Chopping: 98 oz (2.9L)
                    Single Chop:    179 oz (5.3L)
                    Twin Chop+:    193 oz (5.7L)




             Heavy Duty Drive Gearbox

             Every 100 hours of operation inspect the oil level in the
             heavy duty drive gearbox. Lower the corn head to
             operating position and remove the check plug (A). If
             additional oil is required, remove the fill plug (B).

             Lubricant Type:
                    Mobil SHC 634

             Capacity:
                    71 oz (2.1L)









             Step-up Gearbox (if equipped)

             Some combine models require a step-up gearbox to
             prevent extreme PTO shaft angles. Every 100 hours of
             operation inspect the oil level. Lower the corn head to
             operating height and remove the check plug (A). If
             additional oil is required, remove the fill plug (B).

             Lubricant Type:
                    Mobil SHC 634

             Capacity:
                    88 oz (2.6L)