Page 26 - Delco Sales Maintenance Guide 2022
P. 26

Sloan G2, ECOS, &
    Solis Maintenance












     1) Unit flashes 4 quick times when user steps within range


     Batteries low; replace batteries AA-Size (4)


     2) Valve does not shut off



     Clean diaphragm or replace (see diaphragm chart)


     Be sure o-ring on top of diaphragm is inserted past the metal inside cover.


     Replace solenoid - 3325453



     3) Not enough water to fixture


     Wrong diaphragm installed. Replace with correct volume diaphragm


     Hand tighten the solenoid. Do not tighten with wrench


     Push diaphragm oring past inside cover.