Page 29 - Delco Sales Maintenance Guide 2022
P. 29

ESS Maintenance Guide






               1) No sensor lights visible



               Replace Sensor - Urinal 3305620; Closet 3305621


               2) Buzz sound at flush but no flush occurs


               Tighten shaft or if worn, replace - 0305165


               3) Short flush


               Replace diaphragm (see diaphragm chart)



               4) No power to valve


               Check transformer (electrician)
               Replace solenoid assembly - 0305329


               5) Control stop or vacuum breaker is leaking



               Replace vacuum breaker kit - 3323182


               Rebuild stop with control stop repair kit - Urinal 3308384; Closet
               3308386




               Routine Maintenance:



               Replace diaphragm (see diaphragm chart)
               Replace vacuum breaker kit - 3323182
               Replace actuator cartridge assembly - 3305043
               Replace shaft - 0305165
               Replace sensor - Urinal 3305620; Closet 3305621