Page 29 - Delco Sales Maintenance Guide 2022
P. 29
ESS Maintenance Guide
1) No sensor lights visible
Replace Sensor - Urinal 3305620; Closet 3305621
2) Buzz sound at flush but no flush occurs
Tighten shaft or if worn, replace - 0305165
3) Short flush
Replace diaphragm (see diaphragm chart)
4) No power to valve
Check transformer (electrician)
Replace solenoid assembly - 0305329
5) Control stop or vacuum breaker is leaking
Replace vacuum breaker kit - 3323182
Rebuild stop with control stop repair kit - Urinal 3308384; Closet
3308386
Routine Maintenance:
Replace diaphragm (see diaphragm chart)
Replace vacuum breaker kit - 3323182
Replace actuator cartridge assembly - 3305043
Replace shaft - 0305165
Replace sensor - Urinal 3305620; Closet 3305621