P. 127
03-41
MAINTENANCE SPECIFICATION - HEATER & AIR CONDITIONING
HEATER & AIR CONDITIONING
MAINTENANCE DATA
The charging capacity of the refrigerant oil
The oil mass of the new compressor is equal to that
While replacing the compressor
poured out of the previous compressor.
03
Supply the 33% of the oil mass required for the
While replacing the evaporator
compressor.
Supply the 20% of the oil mass required for the
While replacing the condenser
compressor.
Supply the 27%~33% of the oil mass required for
While replacing the tube
the compressor.
Pressure value when Low-pressure side 0.2~0.4MPa
the refrigeration system
operates normally High-pressure side 1.2~2.0MPa
TORQUE REQUIREMENTS
Fasteners N•m
The fixed bolts of the pipeline connecting the 21~25
compressor
The fixed bolts of the compressor 40~45
The fixed bolts of the crossbeam 21~28
Bolts of the fixed bracket on the top of the 20~24
condenser
The fixed bolts of the lock on the hatch cover of the 15~18
engine
The fixed bolts on the right side of the HVAV 8~9
assembly
The fixed bolts on the right side of the HVAV 8~9
assembly
The fixed bolts on clamp plate of the air-conditioning 8~9
pipeline
The fixed bolts on the low-pressure line of the air- 8~9
conditioning