MAINTENANCE SPECIFICATION - SUPPLEMENTAL SAFEGUARD SYSTEM
SUPPLEMENTAL SAFEGUARD SYSTEM
MAINTENANCE DATA
SIR System
Working temperature -35~85 ℃
Working voltage 12±3V 03
TORQUE REQUIREMENTS
Fasteners N•m
The fixed bolts of the SRS assembly for the driver 6±1
The fixed bolts of the SRS electric control 9±1
The fixed bolts of bonding on the SRS control unit 9±1
The fixed bolts on the emergency locking retractor 10~14
(ELR) of the life belt for the front
The fixed bolts of the life belt (upper) 45~55
The fixed bolts of the life belt (lower) 45~55
The fixed bolts of the seat belt buckle 45~55