preparing for net zero with natural gas


                 power (CHP) system. Operators can
                 use gas-powered reciprocating gensets
                 to produce power independently from
                 the grid. They can then capture any
                 waste heat and reuse it to heat water
                 and create steam, which can be used
                 for heating purposes. As well as being
                 more efficient than conventional
                 transmission and boilers, CHP requires
                 less fuel to produce the same amount of
                 energy because it uses heat that would
                 otherwise be wasted.
                   CHP can be used in various
                 commercial buildings like hospitals
                 and office blocks as well as residential
                 sites. These units can also be installed
                 in data centres and hospitals, where
                 they can deliver efficient power, reduce
                 emissions and cut energy costs.                                              A CHP UNIT IN A MEDICAL RESEARCH FACILITY
                   These energy-saving capabilities
                 mean that CHP units can reduce   improve efficiency by selecting parts   usage effectiveness (PUE) by 15 per cent.
                 emissions and improve air quality —   that have been approved by the original   Therefore, while the 2050 deadline for
                 vital steps in the net zero pledge. Less   equipment manufacturer (OEM). Using   net zero is still a few decades off, this
                 fuel is combusted than would be with a   genuine parts will also ensure that the   high-consumption industry is already
                 coal-fired power station, which results   unit runs as intended, with optimal   considering greener alternatives.
                 in lower CO₂, NO  and SO  levels. While   performance and reduced downtime.   There is no straight switch from
                                    X
                              X
                 the process still produces the first two of   Operators can also be safe in the   diesel to gas and it is not as simple as
                 these pollutants, businesses will reduce   knowledge that the components will not   converting a generator — there are some
                 their emissions by at least 20 per cent   be rejected by the high-pressure unit.   important engineering considerations.
                 by adopting CHP. Generally, the cuts in                           Data centre operators will require a
                 pollution will vary depending on how   DATA CENTRE STANDBY POWER  new genset that has low hours and is
                 long the system has been running.   Data centres are power-hungry facilities   designed to run on natural gas. They
                   There are several ways of reducing   that require uninterruptible power 24   will also need to consider how the new
                 emissions with CHP units. First, the   hours a day, a good example of where   standby genset will fit into the data centre
                 unit should be sized correctly. If the   a big impact can be made. Continuous   and whether a new uninterruptible power
                 system is too small, it will not generate   power is vital in preventing files   system is required.
                 sufficient power to meet demand,   being corrupted, avoiding mainframe   As with CHP, servicing is crucial
                 meaning the business will miss out   malfunction and reducing the chance   and gas engineers can help carry out
                 on the full carbon-saving benefits. On   of money being lost. Because of their   the required maintenance. With gas
                 the other hand, if the unit is too large,   high energy consumption, data centres   generators, the focus is often the mains
                 it will struggle to meet its minimum   emit large amounts of emissions, which   supply that is fed into the generator.
                 load threshold for these benefits to   is a challenge for the net zero pledge.   These gensets may need to be checked
                 be realised. Operators should size   In the already established yet growing   weekly to ensure that everything is
                 their CHP to meet the base load, the   Irish market, data centre expansion   running as it should — engineers can
                 minimum level of demand for energy   is expected to add over one and a half   collaborate with data centre operators,
                 and heat over a certain timeframe.   million tonnes to the country’s carbon   consulting the manufacturer’s
                 Calculating the base load involves   emissions by 2030, according to the   recommendations if required.
                 completing an economic feasibility   Irish Academy of Engineering.  With natural gas producing 99 per
                 study, gathering data on consumption,   Gas is already an established fuel in   cent less sulphur oxides, 80 per cent
                 load profiles and heat-to-power ratios.   data centres. These sites can produce   less nitrogen oxides and 40 per cent
                   Gas engineers and experienced   power themselves using prime gas   less carbon dioxide than diesel, it is no
                 servicing teams can help operators   gensets or as part of a CHP system.   surprise that it will be key in helping the
                 maintain their CHP units, meaning   However, many data centre operators   UK reach net zero emissions. Meeting
                 their full environmental benefits can   still use diesel to power their standby   this ambitious target will require
                 be realised. One way to do this is by   generators because these machines can   converting diesel-heavy industries, such
                 preventing excessive fuel consumption   accept significant load steps quickly   as data centres and investing in gas-
                 to reduce the emissions output. Part   after an outage. As the demand for clean   based technologies like CHP.
                 of the maintenance regime includes   energy increases, there are signs of a
                 checking there is sufficient lube as, if   growing trend towards using natural gas    Finning UK & Ireland, part of Finning
                 not, it can cause extra resistance on the   to power standby gensets too.  International, has a recognised track
                 generator’s cylinder head, gasket and   As the UK moves towards net zero   record for delivering solutions to a diverse
                 seals, increasing fuel consumption for a   emissions, the data centre industry   range of industries including mining,
                 similar heat take-off as beforehand.   has been encouraged to play its part.   quarrying, building and construction,
                   When devising a maintenance    Following the UK climate change   marine, power generation, industrial OEM
                 regime, operators and gas engineers   agreement (CCA) scheme, data centres   and oil and gas. For more information,
                 can maintain carbon-reduction and   have been expected to reduce their power   visit www.finning.com