Page 78 - booklet draft
P. 78

Contactors - A & B circuit.

                     c) The Auxiliary  Contactor  which is  provided in  the  BSW-3 Rotary
                         Switch ensures that HOG coil will not energize; if the ZS couplers
                         are  not  inserted  to the  socket  of  the  LHB  OMS  car/LHB
                         Saloons/LHB Parcel Van.
                        The block diagram with the above modifications is shown below:



































                        COST IMPLICATION:

                        A SUM OF RS. 20,000 (TWENTY THOUSAND ONLY) USED BY DEPARTMENT, BUT

                        WHEREAS REPUTED FIRM HAS GIVEN BUDGETARY QUOTATION FOR ABOVE WORK
                        IS  RS. 68,000 + 18% GST (SIXTY  EIGHT  THOUSAND). BY  CARRYING  OUT

                        ABOVE WORK BY THE ABOVE STAFF, RAILWAY HAS SAVED RS. 48,000 (FORTY
                        EIGHT THOUSAND) FOR EACH POWER CAR. THIS DEPOT IS HAVING 40 NOS. OF
                        SUCH POWER  CARS  APPROXIMATELY RAILWAY HAVE SAVED RS. 48000 X 40

                        NOS. OF  POWER  CARS  IS  RS. 19,20,000 (NINETEEN  LAKHS  TWENTY
                        THOUSAND)