C) To  extend  the  Power  supply  from  the  Power  car  to  the  Non-
                      vestibule end connected LHB
                      EOG  coaches  (LHB  OMS

                      car/LHB  Saloons/LHB  Parcel
                      Van):
                      Control  wires  of  feeder  &
                      HOG contactor are modified

                      to  CLOSE  this  contactors  as
                      to  extend  the  Power  supply

                      from  the  Power  car  to  the
                      Non-vestibule                      end

                      connected             LHB         EOG
                      coaches  (LHB  OMS  car/LHB

                      Saloons/LHB Parcel Van)
                      06 nos. RSW are provided for Feeder-1&2 and HOG by-pass.
                      Modification  is  carried  out  departmentally  on  trial  in  Power  car

                      no.  16851  LWRRM  which  is  in  service  by  Train  no.  02774  SC-SHM

                      Shalimar Express without any failures.
                D) Ladder for attending failures of RMPU on roof top of the AC coach:
                      A  ladder  was  built  with  waste  GI

                      pipes  for  attending  failures  of
                      RMPU  on  roof  top  of  the  AC

                      coach.
                      The  ladder  can  be  shifted  within

                      the shed on its 4 wheels
                E)    Test bench for RMPU controller:

                      To  check  the  working
                      condition                        of

                      Microprocessor                   to
                      operate  equipments  in

                      RMPU  ie.,  Blower  motor,
                      Condenser,  Compressor,
                      etc.,