              Lighting


               To work safely in confined spaces as per the ACOP -
                “Adequate and suitable lighting, including emergency lighting, should be provided. For example, the
                lighting should be specially protected if used where flammable or potentially explosive atmospheres are
                likely to occur. Other gases may be present that could break down thermally on the unprotected hot
                surfaces of a lighting system and produce other toxic products. Lighting may need to be protected
                against knocks (eg by a wire cage), and /or be waterproof. The position of lighting may also be
                important, for example to give ample clearance for work or rescue to be carried out unobstructed.”



               ATEX ZONE 0 PORTABLE LIGHTING

               Our range of lighting is designed and tested to comply with requirements to safely operate in Zone 0 where ignitable concentrations
               of flammable gases, vapours or liquids are present continuously or for long periods of time under normal operating conditions.













               LED-PL1                                            LED-H2
               •  65 Lumen white CREE LED.  •  ATEX Zone 0 compliant.  •  180 Lumen white CREE LED.  •   ATEX Zone 0 compliant.
               •   Durable rubberised    •  Chemical and corrosion resistant.  •  Adjustable rubberised headbands.  •   Safety gas release valve.
                 head and body.          •  Strong ABS housing.   •  IP67 Dust and Water proof.  •   Safety locking battery
               •  Convenient pocket clip.                         •  1m Submersible.            compartment.
               •   Easy press switch ON/OFF                       •  Easy press rubberised switch.  •     Durable synthetic
                 operation.                                       •  90º Rotational head.       industrial rubber impact
               •  Safety gas release valve to                                                   resistant construction.
                  release hydrogen gases.
               •   Safety locking battery                          Code   Description
                 compartment.                                      LED-H1    ATEX Zone 0 140 lumen LED Head Torch
                Code   Description
                LED-PL1  ATEX Zone 0 65 lumen LED Pen Torch

               LED-RA2

               •   210 Lumen white CREE LED.
               •   ATEX Zone 0 compliant.
         Lights, Helmets and Radios - Lighting
               •     Ultra strength
                  polycarbonate housing.                          LED-FL4
               •   Convenient pocket clip.                        •  130 Lumen white CREE LED.  •     Rubberised head for
               •     Durable rubberised head                      •   ATEX Zone 0 compliant,    greater durability.
                  and grips for durability.
                                                                    explosion proof.
               •     Safety locking battery                       •   Safety gas release valve to   •     Industrial strength
                                                                                                polycarbonate housing.
                  compartment.
                                                                    release hydrogen gases.
               •     Easy push switch                             •  IP67 dust and 3M submersible.  •     Detachable pocket clip
                                                                                                included for hands free use.
                  Micro Switch Operation.                         •  Chemical and corrosion resistant.
               •   Impact resistant to 1m.
                                                                   Code   Description
                                                                   LED-FL4   ATEX Zone 0 130 lumen LED compact torch
               Code   Description
               LED-RA2  ATEX Zone 0 270 lumen Right Angle Torch
               Regulation 15 of the Electricity at Work Regulations 1989 states;
               “The purpose of the regulation is to ensure that sufficient space, access and adequate illumination are
               provided while people are working on, at or near electrical equipment so that they may work safely. The
               requirement is not restricted to those circumstances where live conductors are exposed, but applies
               where any work is being done in circumstances which may give rise to danger.”

              [Source]  The Confined Space Regulations 1997 - Approved Code of Practice and guidance - Health and Safety Executive
                 The Electricity at Work Regulations 1989