Page 129 - Arch binder
P. 129
Operable Partitions MODEL 2020 STACK ARRANGEMENTS
10 22 26 (10650)
Standard Perpendicular Stack
Pocket Width Perpendicular stacking allows individual panels to be located at
one (1) or both ends and stored perpendicular to the wall’s
installed position.
*
*
*
Stack Depth
* * Pocket Width
Note:
*** If optional double pocket doors w/ Optional Parallel Stack
expander closure is required minimum
* Stack Depth dimension is 2'-10" [864]. In contrast to perpendicular stacking, Individual Panel
1'-0"
[305] ***
arrangements may also be stored parallel to the wall’s installed
[610] 2'-0" Min. position, at one (1) or both ends.
Optional Remote Stack
For more complex wall system layouts, or when space or other
room constraints dictate, Individual Panels may be located
remotely from the wall’s installed position, at one (1) or
both ends.
Pocket Width
*
*
*
Stack Depth
Stack Depth* Pocket Width**
The overall depth of the stack area, as required for panel storage, The width of the pocket is determined by the widest panel in
is dictated by the total number of panels in the wall system. the wall run. For specifi cation purposes, assume the widest
KWIK-WALL’s Model 2020 - Steel Reinforced panels require an panel is 4'-0" (122 cm) maximum. Pocket width may be
average stack depth of 3 / 4" [83] per panel. To determine the stack calculated as follows:
1
depth, calculate as follows:
If Adjustable or Operable Bottom Seals are specifi ed:
1
Number of Panels x 3 / 4" [83] Panel Width + 7" [178]
1
(allows 3 / 2" [89] for hand clearance on each side)
*Note: Additional stack depth is required for wall systems
If Automatic Bottom Seals are specifi ed:
containing the following type of panels:
3
• Expander Panel Closure or Pass Door Panel: / 4" [19] Widest Panel + 10" [254]
• Hinged Panel(s) Closure: 4" [102] (for actuator clearance on one side)
• Pocket Door(s): 6" [152]
plus
**Note: For wall systems that include Pocket Doors, please
1
reference KWIK-WALL’s “ 2000 Series Pocket Doors” brochure 3 / 2" [89]
for pocket layout dimensions and applications. (for hand clearance on the other side)
8
04-18
Dimensions in [ ] are millimeters. Contact your local distributor for additional assistance or visit www.kwik-wall.com