Page 41 - Arch binder
P. 41
Operable Partitions MODEL 3010 PART 2 - PRODUCT SPECIFICATION
10 22 26 (10650)
2.07 CLOSURE SYSTEMS
6. Optional High Pressure Laminate: consisting of general purpose A. Initial Closure System: The lead panel (the fi rst panel exiting the
plastic laminate pressure bonded to 1/2" [12.7] particle board stack) shall form a seal vertically against a rigid wall surface, as
core, and vertically edge banded if Trimless astragals are accomplished by a (select):
specifi ed. 1. Standard Bulb Seal: consisting of continuous-contact, fl exible
(Note: Acoustical substrate STC ratings apply for High Pressure Laminate vinyl bulb seals installed along the vertical edge of the lead panel
panel construction.) for positive compression against a rigid wall surface.
7. Optional Unfi nished: consisting of panels with exposed 2. Optional Fixed Starter Jamb: consisting of an aluminum
acoustical substrate or steel skins for fi eld applied extrusion, which is permanently mounted to a structural wall
wall covering or painting. surface. The Fixed Starter Jamb shall incorporate a tongue-and-
groove-type vertical astragal for positive interlocking with
B. Finish Material Supplier: Finish material shall be (select):
the lead panel.
1. Standard Factory Supplied: from manufacturer’s standard 3. Optional Adjustable Starter Jamb: consisting of an aluminum
selection of fi nish materials, as specifi ed.
extrusion which is permanently mounted to a structural wall
2. Optional Customer Supplied: from customer’s selection of fi nish surface and is fi eld-adjustable to compensate for out-of-plumb
material, by others, and as approved by KWIK-WALL Company. conditions of the fi xed wall. The Adjustable Starter Jamb shall
C. Finish Material Application: Finish material shall be (select): incorporate a tongue-and-groove-type vertical astragal for
positive interlocking with the lead panel.
1. Standard Factory Applied: by KWIK-WALL's authorized
distributor. Customer supplied fi nish material samples must B. Final Closure System: The fi nal closure panel (the last panel
be submitted to manufacturer for testing and approval prior to exiting the stack) shall form a seal vertically against a rigid wall
acceptance and application. surface. The type of fi nal closure panel shall be (select):
2. Optional Field Applied: by others. 1. Standard Hinged Panel(s) Closure: consisting of a panel(s)
hinged permanently and directly to a permanent wall surface.
2.06 PERIMETER TRIM AND SEALS The Hinged Panel(s) shall be equipped with an adjustable
A. Vertical Trim and Seals: Panels shall have vertical astragals bottom seal, a lap-type extrusion for sealing against its adjacent
containing fl exible vinyl seals and incorporate reversible panel (standard) or (optional) expander mechanism with a
tongue-and-groove-type confi gurations for positive interlocking nominal 5" [127] of travel, activated from the face of the panel
with adjacent panels. Vertical astragal type shall be (select): using a removable wrench, and a fl ush pull handle on each side
of the panel.
1. Standard Trimless Astragal: consisting of an aluminum
extrusion with tongue-and-groove-type vertical astragals. 2. Optional Portal Expander Panel Closure: consisting of an
Vertical trim shall not be permitted on the panel faces, resulting expander mechanism with a nominal 5" [127] of travel, activated
in a minimal groove appearance between adjacent panels. from the face of the panel using a removable wrench. The
Portal Expander Panel shall be hinged to the adjacent panel
2. Optional Cap-type Astragal: consisting of an aluminum and, equipped with an adjustable bottom seal (standard) or
extrusion with tongue-and groove-type vertical astragals for (optional) operable bottom seal, and a fl ush pull handle.
encapsulating and protecting the fi nish material and substrate
along the vertical edge of the panel. 3. Optional Pocket Door(s): (see “3000 Series Pocket Door”
brochure for complete details and specifi cations).
B. Horizontal Top Trim and Seals: Top seals shall consist of fl exible Note: 1. Optional Automatic Bottom Seal is not available in
vinyl sweep seals installed on both sides of the panel. The seals conjunction with Final Closure panel(s).
shall consist of a compressed bulb between two (2) fi ngers of 2. Final closure type selection will vary depending on jobsite
vinyl. Top seal shall be fi xed providing continuous-contact fl exible conditions.
vinyl, which seals against the bottom fl ange of the overhead track.
C. Horizontal Bottom Trim and Seals: Bottom seals shall consist of 2.08 ACOUSTICAL PERFORMANCE
multiple fi ngers of fl exible vinyl for positive contact and sealing A. Certifi cation: The operable wall shall have been tested in an
with various fl oor surfaces. Bottom seal type shall be (select): independent acoustical testing laboratory in accordance with
1. Standard Operable Bottom Seals: consisting of an edge activated ASTM E 90 and ASTM E 413 test procedures.
seal using a removable wrench as supplied by manufacturer. B. STC Rating: The operable wall acoustical performance rating
Bottom seals shall provide 2" [50.8] of nominal travel. shall be based on (select):
2. Optional Adjustable Bottom Seals: consisting of fi eld adjustable, 1. Standard Steel Skins: with a standard rating of 52 STC, or
continuous-contact vinyl sweep seals with 2" [50.8] nominal optional ratings of 46 STC, 50 STC or 56 STC.
3
height with / 4" [19] of adjustment. (Note: Not available with optional Wood Veneer or High Pressure Laminate.)
3. Optional Automatic Bottom Seals: consisting of self-activated 2. Optional Acoustical Substrate: with optional ratings of 43 STC,
seals providing 2" [50.8] of nominal travel. 46 STC, 48 STC or 50 STC.
D. Horizontal and Vertical Panel Trim: All exposed panel trim and
hinges shall be of one (1) similar color (select):
1. Dark Bronze
2. Grey
4
04-18
Dimensions in [ ] are millimeters. Contact your local distributor for additional assistance or visit www.kwik-wall.com