Page 52 - Arch binder
P. 52
Operable Partitions MODEL 3020 PART 2 - PRODUCT SPECIFICATIONS
10 22 26 (10650)
2.01 ACCEPTABLE MANUFACTURER 2.05 FINISHES
A. Operable walls shall be Series 3000, Model 3020 Individual Panels / A. Finish Material Type: Panel fi nish material shall be Class A (except
Multi-Directional as manufactured by KWIK-WALL Company. wood veneer) rated in accordance with ASTM E 84, consisting of
(select):
2.02 PANEL CONSTRUCTION 1. Vinyl: consisting of Type II, reinforced vinyl weighing
A. Panel Dimensions: Standard panel dimension shall be a nominal 21 oz./lin. yd. (651 g/lin. m). Vinyl shall meet or exceed
4" [101.6] thick. CCC-W-408A and CFFA-W-101-D quality standards.
B. Panel Frame: Steel frame shall be 16-gauge galvanneal steel, 2. Optional Upgrade Fabric: consisting of fade and tear resistant
horizontal top cross member shall be minimum 12-gauge fabric that resists water-based stains weighing 13 oz./lin. yd.
galvanneal steel which meets or exceeds ASTM A 653 (403 g/lin. m).
requirements. Frame shall be all-welded construction with steel 3. Optional Basics Carpet: consisting of acoustically absorbent,
corner supports and crossbracing reinforcement. Panel frame shall non-woven needle punch fi bers fused to prevent fraying and
be Class A rated, fi re retardant, non-combustible and non-corrosive unraveling of material weighing 28.5 oz./lin. yd. (884 g/lin. m).
in accordance with ASTM E 84. Basics Carpet shall achieve a minimum NRC (Noise
C. Panel Skins: Panel skins shall be Class A rated (except Wood Reduction Coeffi cient) rating of .20 (applied over gypsum
Veneer and High Pressure Laminate) in accordance with ASTM E substrate) accordance with ASTM C 423.
84. Panel skin material shall consist of (select): 4. Optional Upgrade Carpet: consisting of acoustically absorbent,
1. Standard Steel Skins: consisting of minimum 22-gauge tension- non-woven needle punch fi bers fused to prevent fraying and
leveled galvanneal steel, pressure laminated to a structural unraveling of material weighing 23 oz. / lin. yd. (713 g / lin.
acoustical backer and mechanically fastened to the steel frame m). Upgrade Carpet shall achieve a minimum NRC (Noise
to form a rigid, unitized and structural panel. Reduction Coeffi cient) rating of .25 (applied over gypsum
substrate) in accordance with ASTM C 423.
2. Optional Acoustical Substrate: consisting of structural
acoustical substrate pressure laminated to both sides of the 5.Optional Wood Veneer: consisting of unfi nished fl at cut wood
steel frame to form a rigid, unitized and structural panel. veneer laminated to 1/2" [12.7] thick particle board core. Veneer
shall be book / running matched within a panel, and vertically
3. Optional Wood Veneer: consisting of particle board core covered edge banded if Trimless astragals are specifi ed.
with wood veneer and pressure laminated to both sides of the (Notes: Optional Class "A" rated particle board is available. Acoustical
steel frame to form a rigid, unitized and structural panel.
substrate STC ratings apply for Wood Veneer panel construction..)
4. Optional High Pressure Laminate: consisting of particle board MODEL 3020 PRODUCT GUIDE
core covered with general purpose plastic laminate and Standard Steel Skin Construction
Phenolic backer sheet, which is pressure laminated to both sides STC Panel Thickness Max. Panel Maximum Maximum
of the steel frame to form a rigid, unitized and structural panel. Rating (nominal) Weight lb./ft. 2 Panel Height Wall Width
D. Panel Weight: Maximum panel weight shall be 46 4" [101.6] 8.5 (41 kg/m ) 24' - 2" [7.4] Unlimited
2
5.9 – 12.9 lb./ft. (29 - 63 kg/m ) depending on STC rating,
2
2
2
size and options selected. 50 4" [101.6] 9.5 (46 kg/m ) 24' - 2" [7.4] Unlimited
2
2.03 OPERATION 52 4" [101.6] 9.5 (46 kg/m ) 24' - 2" [7.4] Unlimited
A. Operation shall be Individual Panels with a Multi-Directional track 56 4" [101.6] 12.9 (63 kg/m ) 24' - 2" [7.4] Unlimited
2
system that allows the panels to negotiate 90 “X”, “L” and “T”
o
intersections as required for movement of panels from storage MODEL 3020 PRODUCT GUIDE
location(s) to various installed positions. Panels shall be top Optional Acoustical Substrate Construction
supported by two (2) carriers featuring dual horizontal precision
Max. Panel
Maximum
Maximum
STC
bearings with high strength polymer tires riding on a structural Rating Panel Thickness Weight lb./ft. 2 Panel Height Wall Width
(nominal)
aluminum track.
43 4" [101.6] 5.9 (29 kg/m ) 16' - 2" [4.93] Unlimited
2
2.04 STACK ARRANGEMENTS
46 4" [101.6] 6.6 (32 kg/m ) 16' - 2" [4.93] Unlimited
2
A. Stack Type: Panel storage confi guration shall be (select):
2
1. Standard Perpendicular Stack: consisting of panels stacked 48 4" [101.6] 7.5 (37 kg/m ) 16' - 2" [4.93] Unlimited
perpendicular to the wall’s installed position.
50 4" [101.6] 9.0 (44 kg/m ) 16' - 2" [4.93] Unlimited
2
2. Optional Parallel Stack: consisting of panels stacked parallel to
the wall’s installed position. *Optional Wood Veneer or High Prerssure Laminate only available
3. Optional Remote Stack: consisting of panels located remotely as Accoustical Substrate Construction.
from the wall’s installed position, as shown on submitted shop ** Estimated panel weights are for intermediate panels. Weight may vary
drawings. due to substrate, size, or function of panel. Add 105 lbs [47kg] for pass door.
Add 6 lbs [3kg] per lin ft height for expanders. Add 3.5 to 8 lbs [1.6 to 3.6kg]
B. Stack Quantity: Panels shall be stored in separate stack areas as per lin ft for track.
required for panel storage. *** Standard features can be modifi ed, contact your Kwik-Wall distributor
for the features you want.
**** Horizontal Splice: Heights over 14'2" [4.31] with Acoustical Substrate
require a structural splice. 3
Dimensions in [ ] are millimeters. Contact your local distributor for additional assistance or visit www.kwik-wall.com 04-18
07-15