Page 88 - Arch binder
P. 88
Operable Partitions
10 22 26 (10650) MODEL 3030 PART 2 - PRODUCT SPECIFICATIONS
5. Optional Upgrade Carpet: consisting of acoustically absorbent,
2.01 ACCEPTABLE MANUFACTURER
non-woven needle punch fi bers fused to prevent fraying and
A. Operable walls shall be Series 3000, Model 3030 Hinged Pairs as unraveling of material weighing 23 oz. / lin. yd. (713 g / lin.
manufactured by KWIK-WALL Company. m) Upgrade Carpet shall achieve a minimum NRC rating of
.25 (applied over gypsum substrate) in accordance with ASTM.
2.02 PANEL CONSTRUCTION
A. Panel Dimensions: Standard panel dimension shall be a nominal 6.Optional Wood Veneer: consisting of unfi nished fl at cut wood
4" [101.6] thick. veneer laminated to 1/2" [12.7] thick particle board core. Veneer
B. Panel Frame: Steel frame shall be 16-gauge galvanneal steel, shall be book / running matched within a panel, and vertically
which meets or exceeds ASTM A 653 requirements. Frame shall edge banded if Trimless astragals are specifi ed.
be all-welded construction with steel corner supports and (Notes: Optional Class "A" rated particle board is available. Acoustical
cross bracing reinforcement. Panel frame shall be Class A rated, substrate STC ratings apply for Wood Veneer panel construction..)
fi re retardant, non-combustible and non-corrosive in accordance
with ASTM E 84. 7. Optional Unfi nished: consisting of panels with exposed
acoustical substrate or steel skins for fi eld applied
C. Panel Skins: Panel skins shall be Class A rated in accordance with wallcovering or painting.
ASTM E 84. Panel skin material shall consist of (select):
B. Finish Material Supplier: Finish material shall be (select):
1. Standard Steel Skins: consisting of minimum 22-gauge tension
leveled galvanneal steel, pressure laminated to a structural 1. Standard Factory Supplied: from manufacturer's standard
acoustical backer and mechanically fastened to the steel frame selection of fi nish materials, as specifi ed.
to form a rigid, unitized and structural panel. 2. Optional Customer Supplied: from customer's selection
2. Optional Acoustical Substrate: consisting of structural of fi nish material, by others, and as approved by
acoustical substrate pressure laminated to both sides of the KWIK-WALL Company.
steel frame to form a rigid, unitized and structural panel. C. Finish Material Application: Finish material shall be (select):
D. Panel Hinges: Panel hinges shall be architectural grade, full leaf 1. Standard Factory Applied: by operable wall manufacturer.
butt hinges. Customer supplied fi nish material samples must be submitted
E. Panel Weight: Maximum panel weight shall be to manufacturer for testing and approval prior to acceptance
5.9 - 12.9 lbs./ft. (29 - 63 kg/m ) depending on STC rating, and application.
2
2
size and options selected. 2. Optional Field Applied: by others.
2.03 OPERATION 2.06 PERIMETER TRIM AND SEALS
A. Operation shall be Hinged Pairs, consisting of panels hinged A. Vertical Trim and Seals: Panels shall have vertical astragals
together in groups of two (2), unless otherwise specifi ed. Panels containing fl exible vinyl seals and incorporate reversible tongue
shall be top-supported by one (1) carrier in each panel. and-groove-type confi gurations for positive interlocking with
2.04 STACK ARRANGEMENTS adjacent panels. Vertical astragal type shall be (select):
A. Stack Type: Panel storage confi guration shall be MODEL 3030 PRODUCT GUIDE
Center Stack, consisting of panels stacked on center to the Standard Steel Skin Construction
Max. Panel
STC
Maximum
Maximum
wall's installed position. Rating Panel Thickness Weight lb./ft. 2 Panel Height Wall Width
(nominal)
B. Stack Quantity: Panels shall be stored at (select): 46 4" [101.6] 8.5 (41 kg/m ) 24' - 2" [7.37] Unlimited
2
1. Standard One End: on one end of the wall run.
50 4" [101.6] 9.5 (46 kg/m ) 24' - 2" [7.37] Unlimited
2
2. Optional Both Ends: on both ends of the wall run.
52 4" [101.6] 9.5 (46 kg/m ) 24' - 2" [7.37] Unlimited
2
2.05 FINISHES
56 4" [101.6] 12.9 (63 kg/m ) 24' - 2" [7.37] Unlimited
2
A. Finish Material Type: Panel fi nish material shall be Class A (except
wood veneer) rated in accordance with ASTM E 84, consisting of
(select): MODEL 3030 PRODUCT GUIDE
Optional Acoustical Substrate Construction
1. Vinyl: consisting of Type II, reinforced vinyl weighing STC Panel Thickness Max. Panel Maximum Maximum
21 oz./lin. yd. (651 g/lin. m). Vinyl shall meet or exceed Rating (nominal) Weight lb./ft. 2 Panel Height Wall Width
CCC-W-408A and CFFA-W-101-D quality standards. 43 4" [101.6] 5.9 (29 kg/m ) 16' - 2" [4.93] Unlimited
2
2. Optional Upgrade Fabric: consisting of fade and tear 46 4" [101.6] 2
resistant fabric that resists water-based stains weighing 6.6 (32 kg/m ) 16' - 2" [4.93] Unlimited
13 oz./lin. yd. (403 g/lin. m). 48 4" [101.6] 7.5 (37 kg/m ) 16' - 2" [4.93] Unlimited
2
4. Optional Basics Carpet: consisting of acoustically absorbent, 50 4" [101.6] 9.0 (44 kg/m ) 16' - 2" [4.93] Unlimited
2
non-woven needle punch fi bers fused to prevent fraying and
unraveling of material weighing 28.5 oz./lin. yd. (884 g/lin. m). *Optional Wood Veneer only available as Accoustical Substrate Construction.
Basics Carpet shall achieve a minimum NRC rating of .20 ** Estimated panel weights are for intermediate panels. Weight may vary due
(applied over gypsum substrate) accordance with ASTM C 423. to substrate, size, or function of panel. Add 105 lbs [47kg] for pass door. Add 6
lbs [3kg] per lin ft height for expanders. Add 3.5 to 8 lbs [1.6 to 3.6kg] per lin f
for track.
*** Standard features can be modifi ed, contact your Kwik-Wall distributor for
the features you want.
**** Horizontal Splice: Heights over 14'2" [4.31] with Acoustical Substrate
require a structural splice.
Dimensions in [ ] are millimeters. Contact your local distributor for additional assistance or visit www.kwik-wall.com 04-18
07-15