Page 101 - Tech handbook 2019 rev 6 whyperlinks
P. 101

Filling with lubricating oil

                              1.  Shut-off valve ha remains open
                              2.  Close the shut-off valve at the lowest point of the oil piping (lubricating oil
                                 cooler).
                              3.  Turn 3-way cock h3 into the "Fill" position.
                              4.  Open 2-way valve v2 manually.
                              5.  The difference in level between the oil pan and the fresh-oil tank will cause
                                 the engine lubricating oil to run into the oil pan.
                              6.  Fill the oil pan to the first indicator on the dip stick.
                              7.  Close 2-way valve v2 manually.
                              8.  Run the electrical pre-startup lubrication system for a few minutes to fill the
                                 lubricating oil cooler.
                              9.  Check the oil level once again and, if necessary, fill up as described to the
                                 marking on inspection glass 1.