Filling with lubricating oil
1. Shut-off valve ha remains open
2. Close the shut-off valve at the lowest point of the oil piping (lubricating oil
cooler).
3. Turn 3-way cock h3 into the "Fill" position.
4. Open 2-way valve v2 manually.
5. The difference in level between the oil pan and the fresh-oil tank will cause
the engine lubricating oil to run into the oil pan.
6. Fill the oil pan to the first indicator on the dip stick.
7. Close 2-way valve v2 manually.
8. Run the electrical pre-startup lubrication system for a few minutes to fill the
lubricating oil cooler.
9. Check the oil level once again and, if necessary, fill up as described to the
marking on inspection glass 1.