114   Clinical Manual of Small Animal Endosurgery




                                    Instrument seen on monitor

                       Monitor








                                       Instrument portal  Instrument
                        Site of interest

                     Second instrument
                              portal












                                          Endoscope      Endoscope
                                            portal
             Fig. 4.6  Line drawing illustrating the principle of triangulation: the two instrument portals are
             placed on either side of the scope portal so that all three converge on the area of interest. The
             monitor is placed across the patient from the surgeon.

























                              Fig. 4.7  Two trumpet valve trocars placed, one for the scope (left) and
                              one for an instrument (right).