Alterations in mentation can be associated with or   other causes. It is always valuable information to see
            secondary to a wide variety of disease processes out-  if therapy improves mentation or not. For example,
  VetBooks.ir  side of the neurologic  system  including shock,   hypovolemic animals will have dull mentation as a
                                                         result of decreased delivery of oxygen to the brain. If
            trauma, infectious diseases, inflammatory diseases,
            electrolyte alterations, hypoglycemia, and many
                                                         the patient is resuscitated appropriately, the mental
                                                         status and responsiveness of the patient will improve.
                                                         If the patient is not resuscitated and perfusion to the
                                                         brain is not restored, the mental dullness could pro-
                                                         gress to stupor, obtundation, coma, and even death.

                                                         Temperature
                                                         Monitoring body temperature has been a foundation
                                                         for  assessing  a patient’s  clinical  status since  the
                                                         1800s, and continues to be an important element of
                                                         the PE. Monitoring body temperature in veterinary
                                                         patients is usually done rectally; a rectal temperature
                                                         is considered representative of the core body tem-
                                                         perature. Multiple studies have investigated the accu-
                                                         racy of rectal temperature monitoring compared to
                                                         the gold standard of core body temperature measure-
                                                         ment: pulmonary artery thermometry.  There is a
                                                         strong correlation between  rectal and  pulmonary
                                                         artery thermometry supporting the use of a rectal
                                                         temperature to obtain a core body temperature.
                                                          See Table 1.2 for the normal rectal temperature
                                                         of feline and canine species. Other forms of tem-
                                                         perature monitoring (axillary, aural) are less accu-
                                                         rate. In cats 22% of axillary temperatures and
                                                         49% of aural temperatures differed by more than
                                                         ±0.9°F (±0.5°C) from rectal temperatures. In dogs,
            Fig. 1.6.  The Nova Prime Plus Vet (Nova Biomedical,   98% of axillary temperatures and 56% of auricu-
            Waltham, Massachusetts, USA) unit. This is a sensor
            card-based instrument that can measure a variety of   lar temperatures differed from rectal temperatures
            blood parameters including blood glucose.    by more than ±0.9°F (±0.5°C). While these meth-
                                                         ods may seem attractive in recalcitrant patients,
            Table 1.5.  Commercially available point-of-care blood glucose and ketone meters.
                                                     Time to    Sample
                                BG/                   results   volume               Strip/cartridge/
            Analyzer            Ket       Range     (seconds)    (μL)   Sample type  sensor card
             Nova Vet Meter a   BG     20–600 mg/dL    4          0.4   Whole blood  Strip
                                Ket    0.1–8 mmol/L    10         0.8   Whole blood  Strip
             Precision Xtra b   BG     20–500 mg/dL    5          0.7   Whole blood  Strip
                                Ket    0.1–8 mmol/L    10         0.7   Whole blood  Strip
             i-STATt b          BG     20–700 mg/dL   120       65–95   Whole blood  Cartridge
             Nova Prime Plus Vet a  BG  15–500 mg/dL   60        135    Whole blood  Sensor card
                     ®
             AlphaTRAK  2 c     BG     20–750 mg/dL    5          0.3   Whole blood  Strip
                                                                                       c
                                            b
            a Nova Biomedical, Waltham, Massachusetts, USA;  Abbott Point of Care, Abbott Laboratories, Abbott Park, Illinois, USA;  Zoetis,
            Parsippany, New Jersey, USA.
            BG, blood glucose; Ket, ketones.