Communications to Controllers                        System Recipe Screen (cont'd.)

         Acri-Data  offers  numerous  communication  choices  Acri-Data can create as many System Recipes as the
         ranging  from  simple,  point-to-point,  wired  serial  storage capacity of the hardware permits, typically
         communication  and  wired  Ethernet.  Most  Acrison  many thousands. System Recipes can be edited off-
         controllers must be equipped with optional commu-    line with a standard text editor, if desired.
         nications  modules  for  use  with  Acri-Data.  Various
         configurations are available including those that use
         Gateway Devices from Acrison, or from third party     Password Protection
         manufacturers. Acri-Data can be configured in many
         ways to achieve the communications required by the    Up to 10 passwords may be defined in the Acri-Data
         user. Contact Acrison for special requirements.       Program. Three levels of access are provided as
                                                               follows:
         Configuration of Acri-Data is accomplished via the
         Communications Screen.                                  MONITOR:

         Acri-Data directly supports Modbus/TCP operating as     When Acri-Data is first started, or when a user
         a master.                                               logs off, it is in Monitor Mode. The operator
                                                                 may  only  view  screens  and  cannot  change
         Highest performance is achieved with direct cable serial  any set points or activate any commands or
         COM port connections using Acrison's DC protocol.       functions.
         Baud rates from 9,600 to 57,600 are supported for
         serial communications.                                  USER:
                                                                 This mode requires a password to be entered
                                                                 and limits functions and access to those features,
         Multi Screen                                            which  an  operator  would  typically  require.
                                                                 System Recipes, for example, may be loaded
         Multiple  parameter  values  may  be  sent  to  one  or  but cannot be created.
         more feeder controllers, without using a recipe, via
         the Multi Screen.                                       SYSTEM:
                                                                 This  password-protected  mode  permits  full
                                                                 access to all functions and features.
         System Recipe Screen

         Three types of System Recipes are available in Acri-
         Data. Data Recipes containing only parameter values,
         graphical recipes containing the System Screen design,
         and graph plus data recipes, which contain both data
         and graphical information. Data Recipes can be cre-
         ated  while  Acri-Data  is  operating  on-line  and  any
         recipe may be loaded "on-the-fly" without stopping
         the system. Each recipe is a text file, which can consist
         of up to 27 selected parameters and modes in each
         feeder controller (user selectable); the identification
         of the feeders that were selected for the system; the
         design of the System View Screen, plus optional com-
         mands to automatically run or stop a system of feeders
         when the recipe is loaded. System Recipes require a
         system level password.