■ System Confi guration Examples



             I/O Control

             Operation data (travel amount, speed, etc.) is set in the driver
                                                                   Easy Control  Low-Cost Design  Space Saving
             in advance. When a signal is input from the directly connected
             PLC, operation is performed using the setting data. A positioning   Power  CPU
                                                                   Supply      Positioning
             module and pulse generator are not necessary, thus saving   I/O   Module Not
             space and simplifying the system.                                 Required
             This kind of                   Use of switches instead
                           START  STOP  START  STOP
             confi guration is              of PLC. Execute operation
                           CCW  CW  CCW  CW
             possible ▶                     data directly from I/O.
                               Switch Box


             FA Network Control Via Network                     Modbus (RTU) Control
             Converter
                                                                RS-485 communication can be used to set operating data
                                                                and parameters, as well as input operation commands.
             All FA network types are supported when a network
                                                                The protocol is Modbus (RTU) compatible, and can be
             converter is used. The setting of operating data and
                                                                easily controlled from a PLC or other device.
             operation commands input is performed from the network.
             Multiple motors can be connected to and controlled by a   Easy Control  Simple Wiring  Supports Serial Modules of Various Manufacturers
             single converter without the need to increase the number
             of host masters, contributing to a reduction in total costs.  Power  CPU   Maximum Connection for 31 Axes
                                                                  Supply
               Easy Control  Simple Wiring  Multi-Axis Control at Low Cost
               Power   CPU
               Supply     Network    ● Reduces the increase
                         Converters
                                       of master devices when       Serial
                                       multiple units are in use  Communication
                                                                    Unit
                                     ● Unifi ed control of motors
                                       and actuators             ▼ This confi guration is also possible
                                     ● Easy control with I/O sense,
               FA Network              even over a network                              Mount an RS-485 communication
                 Unit                                                           Serial
                                                                             Communication  board in a computer to carry out
                              RS-485                                           Board    setting and operation, instead of
                                                                                        using a PLC.
                                       [Linking of Multiple Drivers]
                                        Maximum 16 axes               PC
                                                                                        Direct connection to a touch
                                                                                        screen instead of using a PLC.
                                                                                        Setting operation data and
                                                                                        parameters, checking alarm
                                                                                        history and trial runs are possible,
                                                                   Touch screen
                                                                  (Panel computer)      making a PLC unnecessary.
                Connection guides have been prepared when communicating   Usable screen samples and operating manuals have
                    using the PLCs and FA network from the following   been prepared when the touch screens from the following
                           manufacturers. (Download)                     manufacturers are connected. (Download)
               • OMRON Corporation   • Yaskawa Electric Corporation  • Schneider Electric Co., Ltd.
               • Mitsubishi Electric Corporation  • Keyence Corporation  • Mitsubishi Electric Corporation  • Keyence Corporation
               • Hitachi Industrial Equipment Systems Co.,Ltd.    • Hakko Electronics Co., Ltd
               • Fuji Electric Co., Ltd.