P. 196
Control Measures for Powered Forklift Trucks
Diesel powered trucks
• Operated in a well-ventilated area.
• Storage limited to minimum quantity.
• Keep suitable fire extinguishers in the storage area.
• Turnoff engine before re-fuelling.
• Spill procedures must be developed, Spills must be cleaned immediately.
• Use PPE, gloves, goggles while handling diesel.
Battery powered trucks
• Charge batteries in a well-ventilated area to dissipate heat.
• When charging batteries, keep the battery vent caps in place to prevent electrolyte spray.
• wear safety glasses and a face shield for protection against electrolyte splash or spray.
• charging station must be equipped with a hoist to avoid manual handling risk.
• No smoking or performing activities which may produce source of ignition.
• Use suitable PPE insulated gloves, shoes to avoid electrocution.
Liquified Petroleum Gas
• Operated in well-ventilated area.
• Check for any leaks prior to start operation.
• LPG cylinders become cold during operation, use gloves while changing cylinders.
• Suitable fire extinguisher must be fitted to the forklift.
• Use hoists to lift cylinders to avoid manual handling risk.
• Provide well-ventilated storage facility for LPG cylinders.
ENSIGN | Unit IG2 – Element 6 – Musculoskeletal 20
Health