Control Measures for Powered Forklift Trucks


               Diesel powered trucks

               • Operated in a well-ventilated area.
               • Storage limited to minimum quantity.
               • Keep suitable fire extinguishers in the storage area.

               • Turnoff engine before re-fuelling.

               • Spill procedures must be developed, Spills must be cleaned immediately.
               • Use PPE, gloves, goggles while handling diesel.


               Battery powered trucks

               • Charge batteries in a well-ventilated area to dissipate heat.

               • When charging batteries, keep the battery vent caps in place to prevent electrolyte spray.
               • wear safety glasses and a face shield for protection against electrolyte splash or spray.

               • charging station must be equipped with a hoist to avoid manual handling risk.
               • No smoking or performing activities which may produce source of ignition.

               • Use suitable PPE insulated gloves, shoes to avoid electrocution.


               Liquified Petroleum Gas

               • Operated in well-ventilated area.
               • Check for any leaks prior to start operation.

               • LPG cylinders become cold during operation, use gloves while changing cylinders.
               • Suitable fire extinguisher must be fitted to the forklift.

               • Use hoists to lift cylinders to avoid manual handling risk.
               • Provide well-ventilated storage facility for LPG cylinders.