Page 227 - IGC BOOK
P. 227

Neither device can estimate the concentration of the dust cloud but may indicate that air monitoring
               is required.

















                                                  Tyndall Beam Apparatus.



               A quantitative indication of a gas or vapour can be achieved using a stain tube detector (grab
               sampler). A sample of air is drawn over crystals in a calibrated tube via a hand pump. The
               gas or vapour needs to be identified before this method is used as the specific tube for the
               substance should be obtained.



               The presence of a hazardous substance causes the crystals to change colour. The tube is
               calibrated  so  that  the  extent  of  the  crystal  colour  change  along  the  tube  indicates  the
               concentration in parts per million (ppm) of the hazardous substance in the air sample.

               There are over 200 tubes available, e.g. oxygen, carbon monoxide, sulphur dioxide, H2S,
               acetone, etc.


               An extension tube is available to permit sampling in a confined space without the tester
               having to enter the space.




















                              Stain Detector Tube.