Page 61 - PIGNAT catalogue 2020 GB_092020
P. 61

MULTI - EXCHANGERS




          BET/3000  THREE-EXCHANGER TEST RIG


                                                                 ➢    Compare three industrial heat exchangers with identical
                                                                      surface areas

                                                                 ➢    Two technology (tubular, plates) same material

                                                                 ➢    Two materials (stainless steel, glass) same technology


                                                                 Study the parameters affecting heat transfer
                                                                      Exchanger materials: glass, stainless steel
                                                                      Regime: turbulent, laminar
                                                                      Circulation: co-current, counter-current
                                                                      Thermal transfer fluid used: hot water, steam

                                                                 Characterize and compare heat transfers
                                                                      Thermal balance
                                                                      Yield
                                                                      Overall experimental and theoretical heat exchange coefficient K

                                                                 Study the condensation of steam

                                                    www.pignat.com
                                                  www.pignat.com         glass/stainless   steel    • Manometer.

                                                                     General specifications

                                                                                                Instrumentation
                    Supervision - Data acquisition               •  ECH1: plate exchanger, stainless  • Temperature probes Pt100Ω.
                                                                                          • Flowmeters.
                                                                  steel.

                                                                 •  ECH2:
                                                                  exchanger, SURLYN coated. Tube
                                                                  with  baffle-plates,  composed  of
                                                                  thirteen SS tubes.

                                                                 •  ECH3:  glass/glass  exchanger,
                                                                  SURLYN  coated.  Tube  with
                                                                  baffle-plates,  composed  of  glass
                                                                  tubes.

                                                                 For each of these three exchangers:
                                                                 •  Two   three-way   valves   for
                      Historical and real time curves             selection  of  the  direction  of
                                                                  circulation.
           The design of this unit allows the study of three industrial exchangers
           with  identical surfaces:  a  plate heat exchanger, a  glass  shell and  SS
           tube heat exchanger and a glass shell and glass tube heat exchangers.   •  Heating unit.
                                                                                          200 - 400 V
                                                                                                           20  kg/h
                                                                                                    Water
           Two  three‐way  valves  allows  the  study  in  co‐current  and  counter-  •  Steam  circuitry:  flowrate  and   3ϕ - 50/60 Hz   1000 L / h   1 bar max
           current flow in each heat exchanger.                   bottling   of   condensate
                                                                  setting valves.     Dim (frame): 200 x 95 x 200 cm  -  200 kg
           The hot water flow rate is adjusted on two flowmeters by two control
           valves than can choose to feed upwards one of the head exchangers.

           Condensation operation
           Steam, expanded, is injected into the glass- glass heat exchanger 4.
           Formed condensates are discharged at the bottom and the flow rate
           is measured by potting.                                                       Option

           Over each exchanger, four temperature sensors make it                 Steam generator
           possible to produce a precise heat balance.




                                              The third heat exchanger used to study the heat transfer
                                              during condensation (steam generator option)


                               Heat exchange
                                                                                                             61