Page 302 - UK Continuing Airworthiness Regulations (Consolidated) 201121
P. 302

Part ML - ANNEX Vb - Continuing Airworthiness Requirements (Lite)


                                          initially disregarded by the owner, CAMO or CAO.
             ML.A.302(d) AMC1     Aircraft maintenance programme
                                   This AMC contains an acceptable MIP for aeroplanes of 2 730 kg maximum take-off mass (MTOM) and
                                   below, and for ELA2 aircraft other than airships, grouped in the following categories:
                                        -  aeroplanes of 2 730 kg MTOM and below;
                                        -  ELA2 sailplanes and ELA2 powered sailplanes; and
                                        -  ELA2 balloons.
                                   These MIPs already comply with the requirements of ML.A.302(d) and may be used in order to define the
                                   basic information for the maintenance programme as required by ML.A.302(c)(2)(a). However, the
                                   maintenance programme must be customised as required by ML.A.302(c)(5), which may be achieved by
                                   using the standard template contained in AMC ML.A.302.
                                   It should be noted that using the 1-month tolerance permitted by ML.A.302(d)(1) for the annual inspection
                                   may result in an expired ARC.
                                   MIP for aeroplanes of 2 730 kg MTOM and below
                                   To be performed at every annual/100-h interval, whichever comes first.
                                   A tolerance of 1 month or 10 h may be applied. The next interval shall be calculated from the time the
                                   inspection takes place.
                                   Note 1: Use the manufacturer’s maintenance manual to accomplish each task/inspection.
                                   Note 2: Proper operation of backup or secondary systems and components should be performed
                                   wherever a check for improper installation/operation is carried out.
                                   ______________________________________________________________________________________
                                   MIP for ELA2 sailplanes and ELA2 powered sailplanes
                                   To be performed:
                                        -  every 100h/annual interval (for TMGs), whichever comes first; or
                                        -  every annual interval (for the rest).
                                   A tolerance of 1 month or 10 h, as applicable, may be applied. The next interval shall be calculated from
                                   the time the inspection takes place.
                                   Note 1: Use the manufacturer’s maintenance manual to accomplish each task/inspection.
                                   Note 2: In the case of TMGs, it is acceptable to control the hours of use of the aircraft, engine and propeller
                                   as separate entities. Any maintenance check to be carried out between two consecutive 100-h/annual
                                   inspections may be performed separately on the aircraft, engine and propeller, depending on when each
                                   element reaches the corresponding hours. However, at the time of the 100-h/annual, all the elements must
                                   be covered.
                                   Note 3: Proper operation of backup or secondary systems and components should be carried out
                                   wherever a check for improper installation/operation is performed.
                                   ______________________________________________________________________________________
                                   MIP for ELA2 hot-air balloons
                                   To be performed at every 100-h/annual interval, whichever comes first.
                                   A tolerance of 1 month or 10 h may be applied. The next interval shall be calculated from the time the
                                   inspection takes place.
                                   Note 1: Use the manufacturer’s maintenance manual to accomplish each task/inspection.
                                   Note 2: Proper operation of backup or secondary systems and components should be carried out
                                   wherever a check for improper installation/operation is performed.




































     20 November 2021                                                                                       302 of 412
   297   298   299   300   301   302   303   304   305   306   307