             ML.A.302(d)(2) GM1   Aircraft maintenance programme
                                   OPERATIONAL TEST AND FUNCTIONAL TEST
                                   An operational test (or operational check) is a task used to determine that an item is operating normally. It
                                   does not require quantitative tolerances.
                                   A functional test (or functional check) is a quantitative check to determine if one or more functions of an
                                   item performs within the limits specified in the appropriate maintenance data. The measured parameter
                                   should be recorded.
             ML.A.302(d)(2)(d) GM1  Aircraft maintenance programme
                                   OPERATIONAL TEST OF TRANSPONDER
                                   A transponder test that is carried out in accordance with EASA SIB 2011-15 or US Title 14 CFR Part 43
                                   Appendix F is considered to include the MIP task described in ML.A.302(d)(2)(d).
             ML.A.303             Airworthiness directives
                                   Any applicable AD must be carried out within the requirements of that AD unless otherwise specified by
                                   the CAA.