Page 40 - Vessel Sanitation Program 2018 Construction Guidelines
P. 40

VSP 2018 Construction Guidelines



                          6.3.3.2       No Sharp Corners
                                        Ensure that NONFOOD-CONTACT SURFACES subject to FOOD or
                                        beverage spills have no sharp internal corners and angles. Examples of
                                        these areas are waiter station work surfaces, beverage stations,
                                        technical compartments with drain lines, mess room soiled drop-off
                                        stations, and bus stations.

                          6.3.3.3       Compatible Metals
                                        Use compatible metals to minimize corrosion due to galvanic action or
                                        to provide effective insulation between dissimilar metals to protect
                                        them from corrosion.


                   6.4    Bulkheads, Deckheads, and Decks

                       6.4.1    Exposed Fasteners
                                Do not use exposed fasteners in BULKHEAD and DECKHEAD construction.

                       6.4.2    Seams and Penetrations
                                Seal all SEAMS between adjoining BULKHEAD panels and adjoining
                                DECKHEAD panels and between BULKHEAD and DECKHEAD panels.

                          6.4.2.1       Seal Seams
                                        Seal SEAMS greater than 0.8 millimeters (1/32 inch), but less than
                                        3 millimeters (1/8 inch), with an appropriate SEALANT or appropriate
                                        profile strips.


                          6.4.2.2       Cover Gaps
                                        Cover all GAPS greater than 3 millimeters (1/8 inch) with appropriate
                                        profile strips.

                          6.4.2.3       Seal Penetrations
                                        Seal all BULKHEAD, DECKHEAD, and deck penetrations through
                                        which pipes or other conduits pass, including those inside technical
                                        compartments. Use durable and NONCORRODING collars where
                                        GAPS are greater than 3 millimeters (1/8 inch).

                       6.4.3    Bulkheads
                                Reinforce all BULKHEADS sufficiently to prevent buckling or to prevent the
                                BULKHEAD from becoming detached under normal operating conditions.


                       6.4.4    Penetrations
                                Weld door penetrations penetrations around fire doors, in thresholds, and in
                                BULKHEAD openings so there are no exposed voids. Ensure locking/latch pins
                                insert into closed locking pin recesses. See Figure 7.








                                                             24
   35   36   37   38   39   40   41   42   43   44   45