Page 30 - Seametrics Product Catalog 2015_062415
P. 30

PS40                                                                        FLOW METER                                         BReladck+- 1G0ro-3u2ndVDC
Pulse Splitter
                                                                                                                                    INPUT
FEATURES
• Rugged ABS plastic housing                                                BROeladUckT+P- PPUuuTllssee  PS40                  BROeladUckT+P- PPUuuTllssee
• Optoisolated Transistor
	 and relay outputs

APPLICATIONS
• Cooling tower/boiler water treatment
• Pacing chemical metering pumps
• Driving multiple pumps, counter timers,

  remote totalizers

GENERAL INFORMATION                                                          DIMENSIONS                                                                       1.107”
                                                                                                                                                            [28.12mm]
The PS40 is a low-voltage device that allows a Seam-                                                                   4.625”
etrics flow sensor to drive multiple (up to four) pulse-                                                           [117.48mm]  00.190”                        2.845”
responsive devices, such as solenoid-driven chemical                                                                           [04.83mm]                    [72.26mm]
metering pumps, counter timers, or remote totalizers.                          4.462”
It requires an external DC power supply for operation                       [113.33mm]
and can provide power to a single low power Seamet-
rics flow sensor, such as an MJE meter. It can also be
used with a dry contact sensor, such as the MJR reed
switch meter.

SPECIFICATIONS*                                                                5.130”
                                                                            [130.30mm]

Power    10 - 32 Vdc

Relay    OCopnetraactitosn=al2f5re0qmueAnmcya=x,5306HVzdmc maxax, 3W max

Optoisolation 10 mA max @ 30 Vdc max

Outputs  TOhnreeeFoorpmenCcroelllaeyctor optoisolated

*Specifications subject to change • Please consult our website for current
data (www.seametrics.com).

17
   25   26   27   28   29   30   31   32   33   34   35