To create future value company 3S KOREA                                                                                                                                                                                              3S
            Clean Room                                                                                                                                                                                                                           KOREA




            실내 기류방식에 따른 적용분야 및 장점                                                                                                           Clean Room 구성의 특징 및 장점
                                                                                                                                            Feature and advantage of clean room Configuration
                 구  분        수직층류방식           수평층류방식             난류방식              혼류방식              터널방식
                         M1.5~3.5          M3.5             M4.5~6.5          M4.5~6.5           M1.5~3.5
            청정도                                                                                                                             최근 에너지 문제가 대두 되고 있는 현시점에 소요 동력은 전기적인 에너             측정 및 제어가 자동으로 이루어지며 필요에 따라 System의 운영이 자
                         (Class 1~100)     (Class 100)      (Class1,000~100,000)  (CLASS1,000~100,000)  (Class1~100)
                                                                                                                                            지를 필요로 하고 있습니다. SYSTEM 운영에 필요한 소요 동력을 최소화           동으로 진행 되어 항상 최상의 조건을 유지할 수 있도록 구성.
            가동시          작업자로부터의           상류의 발진이 하류에      작업자로부터의           Lay-Out에 따라 작업자로   작업자로부터의                                    할 수 있도록 구성 되어 있습니다.                                 Measurement and control are done automatically and the system is operated
            청정도          영향은 적다            영향을 끼친다          영향이 있다            부터의 영향이 조금 있다      영향은 가장 적다                                  At present, where energy problems are emerging, the required power needs   automatically as needed so that it can maintain the best condition at all times.
                                                                                                                                            electrical energy. It is composed to minimize the required power which needs
            운전비          고                 중                저                 중                  중
                                                                                                                                            system operation.
            Lay-Out 변경   용이                곤란               용이                용이                 곤란
                                                                                                                                                             에너지 절감 방안                                            운영의 편의성
            제조 장치        Room안 혹은 Return   Room안 혹은 Return   Room 안부터         Room 안 혹은          Return Space
                                                                                                                                                            Energy saving plan                                  Easy operation
            보수           Space부터 시행        Space부터 시행       시행                Return Space부터 시행  부터 시행
            확장성          곤란                곤란               다소곤란              곤란                 라인마다 증설 가능

                         실 전체 제어 때문에
                                           상류의 발열이                                               작업자마다
            정밀 제어        실내에서의                              불균형 있음            불균형 있음
                                           하류에 영향을 끼친다                                           고정밀도 제어 가능
                         불균형 약간 있음
                          S.A                                                                                                                                                              Clean
                                           S.A         R.A   S.A                S.A              S.A
                                                                                                                                                                                           Room

            형식


                          R.A                                R.A        R.A    R.A               R.A



            Application field and advantage according to indoor air flow system                                                                                운영의 효율성                                           운영의 정밀성
                                                                                                                                                             Efficient operation                               Precise operation

                Division  Vertical laminar flow   Horizontal laminar flow   Turbulent flow  Interflow  Tunnel
                                                                                                                                            장비 사용 중 기기의 소손은 발생 할 수 있는 부분 입니다. 물론, A/S 발생        현장 운영시 적용 계측기기의 정확도를 수시로 확인 하기 위한 System
                         M1.5~3.5          M3.5             M4.5~6.5          M4.5~6.5           M1.5~3.5                                   시 최대한 빨리 대응하여 설비의 운전시간을 최대화 할 수 있는 방안으로             이 적용 되어 오차 발생시 현장에서 바로 보완 적용을 할 수 있도록 구성
            Cleanliness
                         (Class 1~100)     (Class 100)      (Class1,000~100,000)  (CLASS1,000~100,000)  (Class1~100)
                                                                                                                                            구성 하기 위하여 각 기기의 구성을 최대한으로 분리 적용 하여 구성 하였            되어 정밀도 높게 운영이 된다.
            Cleanliness in   A Little impact from   upstream affects  Effect from workers  A Little impact from work-  Minimum effect from   습니다. 이는 100% 운영은 아니더라도 SYSTEM을 최대한으로 운영 할          It is constructed so that it can be supplemented directly on the spot when an
            operation    workers           downstream                         ers depending on lay-out  workers                             수 있도록 구성.                                           error occurs and it operates with high precision because the system is applied
            Operation rage  High           Medium           Low               Medium             Medium                                     Damage to the equipment may occur during use of the equipment. Of course,   to confirm the accuracy of the measuring equipment used during field opera-
                                                                                                                                            in order to maximize the operation time of the equipment in response to the A/  tion.
            Lay-out change  Easy           Difficult        Easy              Easy               Difficult
                                                                                                                                            S occurrence as soon as possible, the configuration of each device is maximally
                         Inside room or starting   Inside room or starting   Starting from Inside   Inside room or starting   Starting from Return
            Maintenance                                                                                                                     separated and applied. It is configured to operate the system as much as possi-
                         from Return Space  from Return Space  room           from Return Space  Space
                                                                                                                                            ble even though it is not operating at 100%.
                                                                                                 Extension possible
            Extendability  Difficult       Difficult        Pretty Difficult  Difficult
                                                                                                 per line
                         Occurred slight imbal-
            Precision    ance in the room due to   Upstream affects down-  Imbalance occurrence  Imbalance occurrence  High precision control   냉동창고 설계 조건                                      Refrigerated warehouse design conditions
            control                        stream                                                of each worker
                         total control
                                                                                                                                            발주자의 일반적인 요구조건                                      General requirement of the client
                          S.A                                                                                                               ・ 창고 고내온도 편차 최소화                                    ・ Minimization of internal warehouse temp. deviation
                                           S.A         R.A   S.A                S.A              S.A
                                                                                                                                            ・ 물류창고 냉동기 가동에 따른 민원 발생 최소화 (소음, 악취, 백연 발생          ・   Minimization of complaints caused by operation of refrigerator in logistics
                                                                                                                                                                                                  warehouse (responding to noise, odor, white smoke occurrence problem)
                                                                                                                                              문제 대응)
            Type                                                                                                                                                                                ・  energy-saving warehouse
                                                                                                                                            ・ 에너지 절약형 창고
                                                                                                                                                                                                ・  Applicable facility configuration in case of equipment failure (Secured back
                                                                                                                                            ・ 설비 고장시 대응 가능형 설비 구성 (Back Up 설비 확보)
                                                                                                                                                                                                 up facility)
                          R.A                                R.A        R.A    R.A               R.A                                        ・ 비독성 냉매 사용으로 민원 발생 배제 (NH3 냉매 사용 금지)
                                                                                                                                                                                                ・  Use of non-toxic refrigerant eliminates complaints (NH3 refrigerant prohibited)  68