Page 20 - Hydra-matic 6 Speed RWD Technician's Guide (October 2005)
P. 20

RANGE REFERENCE CHART


                                                                           HYDRA-MATIC 6L80 GEAR RATIOS
                                                                          1ST       4.027    4TH       1.152
                                                                          2ND       2.364    5TH       0.852
                                                                          3RD       1.532    6TH       0.667
                                                                                             REVERSE   3.064






































                             SHIFT  SHIFT  1-2-3-4 CL  2-6 CL  3-5 REV CL  LOW REV                        LOW
                  RANGE  GEAR  SOL  SOL  PC      PC      PC  4-5-6 CL PC  1-2-3-4  3-5 REV.  4-5-6  2-6  LOW & REV.  CLUTCH
                              1    2    SOL 5 N.L.  SOL 4 N.L.  SOL 2 N.H.  SOL 3 N.H.  CLUTCH  CLUTCH  CLUTCH  CLUTCH  CLUTCH  SPRAG
                  PARK   P    ON   ON    OFF    OFF    OFF     ON                                APPLIED*
                   REV   R    ON   OFF   OFF    OFF     ON     ON           APPLIED              APPLIED
                   NEU   N    ON   ON    OFF    OFF    OFF     ON                                APPLIED*

                       1st Braking  ON  ON  ON  OFF    OFF     ON    APPLIED                     APPLIED  HOLDING
                        1st  OFF   ON    ON     OFF    OFF     OFF   APPLIED                             HOLDING
                        2nd  OFF   ON    ON      ON    OFF     OFF   APPLIED              APPLIED
                        3rd  OFF   ON    ON     OFF     ON     OFF   APPLIED  APPLIED
                   D
                        4th  OFF   ON    ON     OFF    OFF     ON    APPLIED       APPLIED
                        5th  OFF   ON    OFF    OFF     ON     ON           APPLIED  APPLIED
                        6th  OFF   ON    OFF     ON    OFF     ON                  APPLIED  APPLIED


                NOTE: FOR SHIFT SOLENOIDS 1 AND 2, "ON" = SOLENOID ENERGIZED (PRESSURIZED), "OFF" = SOLENOID DE-ENERGIZED (NO PRESSURE).
                NOTE: FOR PRESSURE CONTROL (PC) SOLENOIDS, "ON" = PRESSURIZED, "OFF" = NO PRESSURE.


                  * = APPLIED WITH NO LOAD.










                                                            Figure 11                                                11
   15   16   17   18   19   20   21   22   23   24   25