Page 24 - Hydra-matic 6 Speed RWD Technician's Guide (October 2005)
P. 24

TORQUE CONVERTER


                     TCC HYDRAULIC CIRCUIT - RELEASE                         TCC HYDRAULIC CIRCUIT - APPLY
            The TCC PC solenoid is OFF, which allows actuator     The  TCC PC solenoid is commanded ON, and the
            feed limit fluid to exhaust through the solenoid. Without  PCS TCC circuit becomes pressurized. PCS TCC fluid
            fluid pressure in the PC TCC circuit, the TCC regulator  pressure moves the TCC regulator valve and the TCC
            valve and the  TCC control valve will remain in the   control vale to the apply position. Drive 1 fluid passes
            released position.                                    through the TCC regulator valve and becomes regulated
                                                                  apply fluid. The regulated apply fluid passage travels
                                                                  to the TCC control valve, and is routed through the
                                                                  valve into the TCC apply circuit.  At the same time,
                                                                  TCC release fluid is routed to an exhaust passage at
                                                                  the  TCC control valve.  The torque converter clutch
                                                                  will now apply and be held until conditions change to
                                                                  determine TCC release.
























                                                 TCC APPLY                                           TCC APPLY




                                                    TCC RELEASE                                          TCC RELEASE






                                                        TCC APPLY                                            TCC APPLY


                      CONV FD LIMIT   CONVERTER FEED LIMIT  EX  COOLER FEED  CONV FD LIMIT   CONVERTER FEED LIMIT  EX  COOLER FEED





                 CONV FEED FROM PRESSURE REGULATOR  ACT FD LIM  PCS TCC  PCS TCC  TCC CONTROL VALVE  DRIVE 1-6  CONV FEED FROM PRESSURE REGULATOR  ACT FD LIM  PCS TCC  PCS TCC  TCC CONTROL VALVE  DRIVE 1-6

                                                   REG APPLY
                                                                                                        REG APPLY







                                                                                            SOL 1
                                       SOL 1  SHTL  TCC REGULATOR VALVE                    SHTL  TCC REGULATOR VALVE
                                                                                                 EX
                                                   EX
                                                                                                       EX
                                             EX
                        TCC                     REG APP                      TCC                     REG APP
                       PRESSURE                                            PRESSURE
                       CONTROL                                              CONTROL
                       SOLENOID                                            SOLENOID
                       N.L. OFF                                             N.L.  ON
                               TCC RELEASE                                           TCC APPLY
                                                            Figure 16                                                15
   19   20   21   22   23   24   25   26   27   28   29