•  LS2 turns on the soap release valve, which
                     mixes with the water input valve to provide a                   Station  Station  Station  Station
                                                                                       1
                                                                                                             4
                                                                                                      3
                                                                                              2
                     wash spray.
                   •  LS3 shuts off the soap valve, and the water input
                     valve remains on to rinse the vehicle.                          Reject  Reject  Reject
                                                                                             lamp
                                                                                                    lamp
                                                                                      lamp
                   •  LS4 shuts off the water input valve and activates              status  status  status
                     the hot wax valve, if selected.                         Product
                   •  LS5 shuts off the hot wax valve and starts the air-
                     blower motor.
                   •  LS6 shuts off the air blower. The vehicle exits the
                     car wash.
                                                                      Inspection zone  Proximity                    Gate
               7.  A product moves continuously down an                               switch
                   assembly line that has four stations, as shown
                   in Figure 12-44.
                   •  The product enters the inspection zone, where   Figure 12-44  Assembly line program for Problem 7.
                     its presence is sensed by the proximity
                     switch.
                   •  The inspector examines it and activates a reject   •  When a defective part reaches station 4, a diverter
                     button if the product fails inspection.               gate is activated to direct that part to a reject bin.
                   •  If the product is defective, reject status lights come   •  Using whatever PLC bit shift register you are most
                     on at stations 1, 2, and 3 to tell the assembler to   familiar with, develop a program to implement this
                     ignore the part.                                      process.



















































               280        Chapter 12  Sequencer and Shift Register Instructions